- 15 -

30. 

PV CURVE SW 

 
Enabling, or disabling PV curve switch for changing PV curves while riding. 
 

 

Enter 

Set PV  

menu and move to 

PV Curve SW 

 with pressing 

'

+

'

, or 

'

-

and press 

'

ENTER

'

 to confirm. 

 

 

Enable, or disable 

PV Curve

 switch with pressing 

'

+

'

, or 

'

-

and press 

'

ENTER

'

 to 

confirm. 

 

 

31. 

MONITORING 

 
Connect 

programmer

 to 

PDCI 

and wait few seconds for activation of 

programmer. 

Fist 

information displayed on the 

programmer

 is software version. 

 
With 

programmer

 you can watch revs, calculated advance ignition angle, TPS 

position...depends on setting in the menu. 
 

 
Information!

 

You can connect, or disconnect 

PDCI 

unit from 

programmer

 any time you want, 

without any harm. It is not important, if motor running, or not and if power supply is 
connected, or not.    
 

Important!

 

Do not use too much force when connecting, or disconnecting 

programmer

 unit! 

 
 
32. 

ERROR REPORTS 

 

PVerr 1 

– position sensor error, or servo motor disconnected  

PVerr 2 – 

servo motor error (short connection) 

 

Summary of Contents for PDCI-NS1V

Page 1: ...t light and power jet output 5 Amp constant spark energy from idle to 13000 RPM 50mJ Important Circuit is fully protected against reverse polarity from firmware 31 170203 Features fast power up also s...

Page 2: ...es Danger of electric shock Avoid connecting PDCI to 12V power supply before connecting to ignition coil High voltage is generated and touching free wires can cause electric shock or damage the unit 1...

Page 3: ...V PARAMETERS SUBMENU Load PV Curve load select PV curve Save PV Curve save new PV curve Set PV Curve PV curve parameters submenu Deviation deviation of PV position Close Position max close PV position...

Page 4: ...g processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to position 0 Later you can save it to any other position 1 or 2 Curve Exa...

Page 5: ...can save it to any other number 1 or 2 Ignition Map Example 5 2 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and press ENTER to confirm Select number of ignition point...

Page 6: ...ded With Advance 1 0 0deg ignition map is unchanged Enter Set Ign menu and move to Advance 1 with pressing or and press ENTER to confirm Set advance with pressing or in 0 1deg steps and press ENTER to...

Page 7: ...ENTER to confirm Enable or disable Smart Shift function with pressing or and press ENTER to confirm 11 REV LIMIT Enter Set Ign menu and move to Rev Limit with pressing or and press ENTER to confirm S...

Page 8: ...atic angle just to have starting point look at drawing below Anticlockwise rotation TRIGGER POINT TDC static angle Clockwise rotation TDC TRIGGER POINT static angle program CDI with measured approxima...

Page 9: ...n the rotor and stator Result of above procedure is very accurate static angle 13 COMPENSATION It is compensation of signal delay from pickup to spark plugs You can check this delay with stroboscope l...

Page 10: ...if TPS enabled Three duty cycle curves for different throttle positions can be programmed Each curve can be programmed in 8 rev points Enter Power Jets menu and move to set Power Jet 1 with pressing o...

Page 11: ...imum open position and confirm calibrating with pressing ENTER or exit calibration with pressing Displayed number should be between 500 and 1010 18 TCT mode Throttle Close spark Termination mode reduc...

Page 12: ...to confirm Change Stop SW Mode with pressing or and press ENTER to confirm 22 Tach Ratio Tachometer output pulse ratio can be set to 1 or 2 pulses per revolution Enter Set Ign menu and move to Tach Ra...

Page 13: ...oint Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to PV curve it is automatically saved to number 0 Later you can save it...

Page 14: ...sition with pressing or and press ENTER to confirm 27 Open Position Max open position must be calibrated Max open position is when curve is set to 100 Open position can be moved to any desired positio...

Page 15: ...mation displayed on the programmer is software version With programmer you can watch revs calculated advance ignition angle TPS position depends on setting in the menu Information You can connect or d...

Reviews: