Current sensor
CT
1) Unscrew the 4 screws (A) of the central cover with a screwdriver.
2) Remove the cover (B), loosen the cable gland (C), and then remove the
stopper (G).
3) Pass the AC cable through the cable gland (C), and connect the phase,
neutral and ground cables to the GRID terminal block.
NOTE
: The loads connected to
the LOAD output will be
regularly powered, even in
the presence of the AC grid..
10. CONNECTING TO THE GRID
The sensor must include all phase cables
entering or leaving the meter
.
HYBRID
PV panels
Protection
switch
Protection
switch
Meter
Critical Loads
Utilities
Batteries
Summary of Contents for Azzurro HYD 3000 ES