62 / 64
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 3K-6KTLM LITE
Unscrew the fixing bolt of the bracket and remove the inverter from the wall.
8.2.
Packaging
If possible, pack the inverter in its original packaging.
8.3.
Storage
Store the inverter in a dry place where the ambient temperature is between -25 and +60°C.
8.4.
Disposal
At the end of its life, dispose of the inverter and the packaging materials in places that can manage and
recycle electrical equipment safely.
9.
Technical specifications
Technical specifications
3000TLM-
L
3600TLM-
L
4000TLM-
L
4600TLM-
L
5000TLM-
L
6000TLM-
L
Input (DC)
Typical power of PV system
3500W
4000W
4400W
5000W
5500W
6600W
Maximum DC power for each
MPPT
2000W
(160V-
520V)
2400W
(180V-
520V)
2600W
(200V-
520V)
3000W
(250V-
520V)
3000W
(250V-
520V)
3500W
(300V-
520V)
Number of independent
MPPTs
2
Number of DC inputs
1 for each MPPT
Maximum DC input voltage
600V
Input activation voltage
120V
Rated DC input voltage
360V
MPPT DC voltage range
90V-580V
DC voltage range at full load 160V-520V 180V-520V 200V-520V 230V-520V 250V-520V 300V-520V
Max input DC current for each
MPPT
11 A / 11 A
Output (AC)
Rated AC output power
3000W
3680W
4000W
4600W
5000W
6000W
Maximum AC power
3000VA
3680VA
4000VA
4600VA
5000VA
600
0VA
Maximum AC current
13.7 A
16.8 A
18.2 A
21A
22.8A
27.3A
Rated AC voltage
L/ N/ PE,220, 230, 240 V
Rated AC voltage range
180V-270V (According to local grid standards)
Rated grid frequency
50 / 60 Hz (According to local grid standards)
Frequency range
47-53Hz / 57-63 Hz (According to local grid standards)
Active power adjustable range
0-100%
Total harmonic current
distortion
<3
%