38 / 64
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 3K-6KTLM LITE
6.
Operating interface
General information in this chapter
This section describes the display and its operation, as well as the buttons and LED indicators of the 3K-6K
TLM-L inverters.
6.1.
Operating panel and display
Buttons and LED indicators
Figure 43 – LCD display with buttons and LED indicators
Main buttons:
Menu/Back: to go back or enter the main menu.
Up: to go up or increase the value by 1.
Down: to go down or decrease the value by 1.
OK/Enter: to confirm the selection and enter the menus
Indicator lights:
Status light (GREEN)
o
Flashing: wait or status check
o
Steady: normal operation
o
Off: temporary or permanent error
Warning light (RED)
o
Steady: temporary or permanent error
o
Off: normal operation
GFCI automatic differential circuit breaker indicating light (RED)
o
Steady: indicates GFCI fault
o
Off: normal operation