30 / 64
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 07/06/2019 Rev. 2.1 “User Manual for 3K-6KTLM LITE
Figure 27 – Connecting the AC output cables (1)
2)
Disassemble the AC connector as shown in the figure below; insert the AC output cable (with its stripped
insulation layers as shown in step 1) through the PG waterproof cable gland.
Figure 28 – Connecting the AC output cables (2)
3)
Connect the AC power cable according to the following criteria:
•
Connect the yellow-green wire to the hole labelled “PE”, and tighten the wire with an Allen key;
•
Connect the brown wire to the hole labelled “L”, and tighten the wire with an Allen key;
•
Connect the blue wire to the hole labelled “N”, and tighten the wire with an Allen key;
Figure 29 – Connecting the AC output cables (3)
4)
Secure the clamping cable gland by rotating it in a clockwise direction, as shown below; make sure that
all the wires are securely connected
5)
Connect the AC output connector to the output terminal of the inverter; turn the AC connector in a
clockwise direction until the fixing device reaches its intended position, as shown below: