Figure 12 - Steps for installing the inverter on the wall
4.
Electrical connections
General information in this chapter
This chapter describes the electrical connections of the 3K-6K TLM-L inverter. Carefully read this section
before connecting the cables.
NOTE:
Before making any electrical connections, ensure that the DC circuit breaker is switched off. Please note that
the capacitors in the inverter may remain electrically charged after the DC circuit breaker has been switched
off. Therefore, it is necessary to wait at least 5 minutes to allow the capacitor to discharge completely.
The inverter must be installed and serviced by professional technicians or electricians.
Attention
The PV modules generate electricity when exposed to sunlight, which can pose a risk
of electric shock. Before connecting the DC input power cord, be sure to disconnect
the strings via the appropriate circuit breakers.
Danger