79
NAK
Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a
minimum message length of 100 when the field will only accept 2 characters.
When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period,
exclamation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable response.
Example:
Example #1:What is the range of possible values for Codabar Coding Enable?
Enter: cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on).
Example:
Example #2: What is the default value for Codabar Coding Enable?
Enter: cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on.
Example:
Example #3: What is the device’s current setting for Codabar Coding Enable?
Enter: cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.
Example:
Example #4: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2
characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the imager with serial trigger commands. First, the imager must be put in Manual/Serial Trigger Mode either by scanning the
Manual/Serial Trigger Mode bar code, or by sending the Manual/ Serial Menu Command . Once the imager is in serial trigger mode,
the trigger is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The imager scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached (see "Read Time-Out"
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the
Standard
Product Default Settings
bar code below.
Standard Product Default Settings
The chart on the following pages lists the factory default settings for each of the menu commands (indicated by an asterisk (*) on the programming pages).
Summary of Contents for ZB-3062
Page 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...
Page 56: ...ZBA Inc 56...
Page 80: ...ZBA Inc 80...
Page 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...
Page 87: ...ZBA Inc 87 13 ASCII Code Table...
Page 88: ...ZBA Inc 88 14 OCR Prog Chart...
Page 89: ...ZBA Inc 89 15 Program Chart...