![ZBA ZB-3062 User Manual Download Page 15](http://html1.mh-extra.com/html/zba/zb-3062/zb-3062_user-manual_3206250015.webp)
ZBA Inc.
15
RS-232 (continued)
Default Setting: Baud Rate: 115200 bps; Data Format 8 data bits, no parity bit, 1 stop bit
Baud Rate
300
600
1200
2400
4800
9600
19200
38400
57600
*115200
Data Bits
sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits,and punctuation),
select 7 data bits. For applications which require use of the full ASCII set, select 8 data bits per character. Default = 8.
Stop Bits
sets the stop bits at 1 or 2. Default = 1.
Parity
provides a means of checking character bit patterns for validity. Default = None.
Data Format
7 Data,1 Stop, Parity Even
7 Data,1 Stop, Parity None
7 Data,1 Stop, Parity Odd
7 Data,2 Stop, Parity Even
7 Data,2 Stop, Parity None
7 Data,2 Stop, Parity Odd
8 Data,1 Stop, Parity Even
*8 Data,1 Stop, Parity None
8 Data,1 Stop, Parity Odd