8
English
Integrated energy meter
Parameter
Value
Certification
MID Class B
Harmonized Standard
EN 50470 -1, - 3
Notified Body
Justervesenet (0431) / NMi Certin (0122)
Rated Voltage
3 x 230/400 V
Rated Current
0.25-5 (32) A
Optical Test Output (must be activated in the app)
10000 imp/kWh
Connectivity
Protocol
Supported standards
4G
LTE Cat M1
Wi-Fi
802.11b/g/n (2.4 GHz)
Bluetooth
Bluetooth v5.1 (BR/EDR/BLE)
Powerline (PLC)
HomePlug Green PHY, 10 Mbit/s
Plug and charge
Hardware support for ISO15118
RFID
ISO/IEC 14443 A (Type A, 13.56 MHz)
ISO/IEC 15693 (Mifare classic, 13.56 MHz)
Integrated RCCB
Parameter
Symbol
Min
Typ
Max
Unit
Residual operating current
I
Δ
n
0.03
A
Operating characteristics
Type B
Making and breaking capacity
Im
500
A
Residual making and breaking
capacity
I
Δ
m
500
A
Rated conditional short-circuit
current
Inc
3
kA
Rated conditional residual short-
circuit current
I
Δ
c
3
kA
Integrated circuit breaker
Parameter
Symbol
Min
Typ
Max
Unit
Manufacturer and part number
Lovato P1 MB 3P C40
Rated current
In
40
A
Curve
C
Nominal short-circuit breaking
capacity
Icn
10
kA
For CE documentation please see zaptec.com/CE-documentation
Summary of Contents for Pro