7
English
Mechanical and installation
Parameter
Test condition
Min
Typ
Max
Unit
Dimensions
H: 392 W: 258
D: 112
mm
Weight
Including backplate
5
kg
Altitude
2000
m
Input cable cross section
2.5
10
mm²
Input cable diameter
13
18.5
mm
Degree of protection
IP54
Noise emission
With fan running
47.5
dBa
Charging mode
Mode 3, case B
Mechanical strength
IK10
Pollution degree
Installation
environment
4
Support for ventilation
According to EN
61851-1 6.3.2.2
No
Access
According to EN
61851-1 5.4
Restricted and non-restricted access
3 . Technical Specifications
General
Parameter
Test condition
Min
Typ
Max
Unit
Rated voltage (Un)
Phase-Neutral
207
230
253
V
Phase-Phase
360
400
440
Rated current (In)
32
A
Rated frequency
50
Hz
Standby power consumption
3
W
Ambient operating temperature
-30
40
°C
Maximum charging power
TN 3 phase @ 32 A
22
kW
TN 1 phase @ 32 A
7.4
IT 3 phase @ 32 A
(Norway only)
12.7
IT 1 phase @ 32 A
(Norway only)
7.4
Protection class
I
Overvoltage category
III