3
Prepare the cable
Recommended cable is round PFXP, Powerflex
or PFSP type with diameter Ø 13–18.5 mm.
Fit the right sealing cone onto the cable before you
connect the cables to the junction box see G or H
for right sealing diameter.
4
Wiring
To limit the risk of leaks in outdoor installations, we recom-
mend connecting the cable to the bottom of the junction
box. If this is not possible, we recommend that the device
be thoroughly sealed and checked in accordance with the
manual, and that other seals be used (Sikaflex or similar).
Location of the charging station/back plate
90–130 cm
Avoid installing the charging
station in areas which are
exposed to direct sunlight.
High temperatures in the
device will reduce the
charging rate.
The back plate must be
mounted on a flat surface.
Well-ventilated area.
Do not install the box
close to heat sources
or in a closed box.
Min. 2
5mm
Max 6mm Max 11mm
x 4
1
Mount the back plate
If the wall structure requires plugs/drilling, you must ensure
that dust and dirt do not get into the junction box.
Screw requirement: Head max 12mm diameter,
Head max height 6mm, length min 25mm.
2
Remove the cover on the junction box
Undo four screws and open the cover to access the
junction box.
Installing and connecting the back plate
It is important not to create any new holes in the back plate. The four existing holes must be used.
Creating new holes in the back plate will invalidate the warranty.