min. 550
min. 560
600
20
A
B
Electrical installation
Warning!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsible if you
do not follow the safety precautions from
the chapter "Safety Information".
This appliance is only supplied with a main ca-
ble.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05 RRF,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
For the section of the cable refer to the total
power (on the rating plate) and to the table:
Total power
Section of the cable
maximum 1380 W
3 x 0.75 mm²
maximum 2300 W
3 x 1 mm²
maximum 3680 W
3 x 1.5 mm²
The earth cord (green / yellow cable) must be 2
cm longer than phase and neutral cables (blue
and brown cables).
Environment concerns
The symbol on the product or on its
packaging indicates that this product may not
be treated as household waste. Instead it
should be taken to the appropriate collection
point for the recycling of electrical and
electronic equipment. By ensuring this product
is disposed of correctly, you will help prevent
potential negative consequences for the
environment and human health, which could
otherwise be caused by inappropriate waste
handling of this product. For more detailed
information about recycling of this product,
please contact your local council, your
household waste disposal service or the shop
where you purchased the product.