Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Auxiliary
29 / 30
Semi-rapid
32
Rapid
42
Oven
50
Grill
59
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Rapid
3.0
0.75
119
Semi-rapid
2.0
0.45
96
Auxiliary
1.0
0.35
70
Oven
2.5
1.0
104
Grill
2.4
1.5
104
Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POWER
kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Rapid
3.0
0.72
88
Semi-rapid
2.0
0.43
71
Auxiliary
1.0
0.35
50
Oven
2.5
1.0
75
Grill
2.4
1.5
75
Gas connection
The gas pipe in the appliance has two endings.
You can connect the gas supply to either one of
them. The pipe that is not used must be
clogged with the pipe closer, which added to
the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible metallic
pipes, make sure they do not come in touch
with mobile parts and they are not squeezed.
www.zanussi.com