A
B
3. Unscrew the screw and slowly pull out the
burner.
1
2
4. Release the burner injector with a 7 mm
socket spanner and replace it with a right
one.
Assemble the burner in a revers sequence.
Replace the gas type sticker near the gas
supply ramp with the one related to the new gas
type.
Adjusting the minimum gas level on the
oven burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the oven functions. If
there is no access to the bypass screw
dismount the control panel before
adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
Changing from natural gas to liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
3. Connect the appliance to the electricity.
Changing from liquid gas to natural gas
24
www.zanussi.com