26
3.6.4 Service Alarm Management
It is possible to adjust some parameters to create an
alarm to remind the operator to arrange for
maintenance. Two different alarms can be displayed
by the in-cab controller:
1.
SEE
warning
that
Standby maintenance hours
exceeded.
2.
Ser warning that Road
mode maintenance hours
exceeded
The parameters to set the intervals are in the
programming menu, at the end of the list.
Total run-time hour counters
•
“EtM” total STAND-BY running hours
counter (display only)
•
“rtM” total ROAD running hours
counter (display only)
These counters display the overall run-time hours of
the machine in road and stand-by operation.
To display these values, access the parameters menu
and select the above parameters.
Partial running hours counters
•
“EtP” partial STAND-BY run-time hour
counter
•
“rtP” partial ROAD run-time hour
counter
These counters are used to generate service alarms
according to service intervals set by means of the
parameters:
•
“SEE” stand-by service interval
•
“Ser” road mode service interval
•
Service alarms are displayed when the value of the
parameter rtP or EtP reaches the limit given by the
parameters SEE or SEr. If the value of the SEE or SEr is
set to 0, the alarm display is disabled and
corresponding counter EtP or rtP remains at 0.
The maintenance alarms SEE or SEr blink on the cab
command module and alternate with the temperature; no
acoustic signal is activated.
Press any key to reset the alarm. However, the alarm will
be displayed every time the unit will be switched on until
the following reset procedure is performed:
Resetting partial run-time counters
1.
access the program menu by pressing the
<PRG> button
2.
select the parameter Etp or rtp by means
of the arrows keyspressing the <SET>
button makes the parameter value blink
3.
hold the <DOWN ARROW> button for 3
seconds and the value resets to 0
4.
press the <SET> button to move to the
next parameter
NOTE:
All the parameters listed above are expressed in
units of 10 hours (example: SEr = 80 means 800 hours).
NOTE
: For full parameter table. See Section 7