25
“dF” = Interval between defrost cycles [hour]
The time interval in hours between the beginnings of
two defrost cycles. Factory set is to 3 hours.
“PAb” = Differential for battery voltage warning
alarm
The battery voltage pre-alarm is activated when
voltage is lower than road mode voltage bt – Pab.
Factory set is 0.7 for Pab.
“Ab” = Differential for battery voltage alarm
If battery voltage (sensed on the startup) is lower than
or equal to the bt – Ab value, the battery alarm is
activated. Factory set is 1.5 for Ab.
“Abd” = Differential for battery alarm
The battery alarm is reset when voltage (sensor
reaches the bt – Pab + Abd value. Factory set is
0.8
for Abd.
“bb” = Start delay after alarm “Ab” [minute]
The time interval between battery alarm stop and unit
resuming operation. Factory set is 15 minutes.
“tS” = Temperature measurement unit
°C or °F. Factory set is °F.
NOTE:
Changing the Parameter tS does not
automatically change the other parameter values if
the units are in degrees.
“EtM” = stand-by working hours
Parameter is based on run-time of the stand-by
compressor. Measured unit used is ten hours
rTM = road working hours
Parameter is based on run-time of the road
compressor clutch. Measured unit used is ten hours.
“SEE” = stand-by mode service interval
Factory set to 80 (800 hours)
“Ser” = road mode service interval
Factory set to 100 (1000 hours)