13
1XA assembly via the Molex 1.25mm Connector
labeled “J9”
. The KEL cable (ordering part number:
CBL-0028-01) and the Molex to BNC cable are sold separately.
Figure 5 Interface Front End PCB
WARNING: ONLY USE THE CORRECT KEL RIBBON CABLE PROVIDED BY Z3 TECHNOLOGY.
Using an incorrect cable can permanently damage the camera body.
(2)
Connect an Ethernet cable from the encoder ethernet port to a switch, router or other DHCP server
on the same network as your Windows PC.
(3)
Connect the 12V power supply to
+12V
on the Encoder and plug into a power outlet.
If Power over Ethernet (PoE) is available, then no connection to the power supply is required.
It will then boot.
Primary KEL
Connector (J5)
Composite (J9)