COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_SUPERVISION
V2
V1
3.
Supported Command Class
Root Device
Suppourt Command class
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
V2
V1
V1
Support S2/s0
ThermostatSetPointType_Heating(set manual temperature)
ThermostatSetPointType_Energy_Save_Heating(set auto temperature)
ThermostatSetPointType_DRY
ThermostatSetPointType_Away_Heating(set away temperature)
ThermostatMode
ThermostatSetPoint
Thermostat Related Specifications
Command
Support
ThermostatMode_OFF(off)
ThermostatMode_HEAT(UI displays Manual)
ThermostatMode_DRY
ThermostatMode_EnergyHeat(UI displays Auto)
ThermostatMode_Away(UI displays Away)
EndPoint2 (floor temperature sensor) command list:
Support command class
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
V2
V1
V1
Support S2/s0
COMMAND_CLASS_THERMOSTAT_MODE
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
COMMAND_CLASS_THERMOSTAT_SETPOINT
V3
V1
V2
YES
YES
YES
YES
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
V2
V3
V1
YES
YES
YES
Support command class
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SENSOR_MULTILEVEL
V2
V1
V1
V1
V5
Support S2/s0
Item
SDK
Explorer Frame Support
Device Type
Generic Device Class
Specific Device Class
Role Type
Routing
Definition
6.82.00
Yes
Thermostat(HVAC)
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_THERMOSTAT_HEATING
Always On Slave (AOS))
Yes
2.
Technical Specifications
SENSOR MULTILEVEL Type support
Air temperature
Scale
Celsius (
℃)
Z-Wave Technical Specifications
1.Supported Notification Repoert and Sensor Type
notifcation Type
POWER_MANAGEMENT
Heat Alarm
Triggering Event
POWER_MANAGEMENT_OVERCURRENT_DETECTED
Overheat detected
Description
Over Current Alarm
Over Heat Alarm
EndPoint1 command list:
Note: the EndPoint01 mirrors equivalent effect root endpoint.
YES
YES
Controlled command class
COMMAND_CLASS_THERMOSTAT_MODE
COMMAND_CLASS_THERMOSTAT_SETPOINT
V3
V2
YES
YES
YES
YES
YES
YES
YES
YES
YES
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_TIME_PARAMETERS
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_METER
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_FIRMWARE_UPDATE_MD
V2
V1
V1
V1
V1
V8
V3
V4
V4
2.Basic set command class
Set the device operation mode as Comfort Mode (Manual Mode) by sending command class basic set = 0XFF.
Set the device operation mode as OFF mode by sending command class basic set = 0x00.
no response from a gateway within 6 seconds, or exclusion failed, “Status” will show “Fail”. If reset
successfully, “Status” will show “Reset OK”.
Note 1: if the device is excluded or reset successfully, the Auto Mode Schedule will be reset to default value.
Note 2: the sent frame of inclusion and exclusion is INFO frame.
YES
YES
YES
YES
YES
YES
YES
COMMAND_CLASS_THERMOSTAT_MODE
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
COMMAND_CLASS_THERMOSTAT_SETPOINT
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_VERSION
V3
V1
V2
V2
V3
V1
V3