- 35 -
Appendix 2
Inngu Laser System
The basic operation of Inngu Laser
1. Turn On/Off the laser
Appendix figure 7. Inngu laser controller
1) Turn On the laser
a)
Ensure that the surrounding temperature is between 15
℃
and 30
℃
before turning on the laser.
b)
Turn on the laser’s main power switch, which is a red switch located
at the back of the laser controller, to power on the laser system.
Please preheat for about 10 minutes if the laser has not been
switched on for a prolonged period of time, and then turn on the key
switch. Please ensure that the emergency button is not in use before
you turn on the main power switch.
c)
Turn on the key switch and the laser will be ready for use after
completing the self-check.
d)
Push down the DIODE-ON button and the LED lights up.
e)
Push down the QS-ON button and the LED lights up.