![background image](http://html1.mh-extra.com/html/yz-systems/njex-zeo-6400/njex-zeo-6400_instructions-and-operating-manual_3804200064.webp)
SECTION 5: SYSTEM CONTROL ELECTRONICS
YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, PA • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 62
NJEX ZEO Version 04/13/2021
11.5.3.4.
Confirm the injection pump is running in a closed loop by noting the verometer
level oscillation
11.5.3.5.
Press the Select Key to start and stop the system again as needed until the
injection pump is primed.
11.5.3.6.
Close V2
11.5.3.7.
Open V8
11.5.3.8.
Open V17
11.5.3.9.
Return to the Home Screen and Press the Right Arrow Key to start the system