FIGURE 11:
Thermostat Wiring –
Single Stage Heat Pump (with YGVI control)
– Single Stage Furnace (Standard ECM)
A007-001
TM9E
TM9X
T*(8,L)X
Single Stage Heat Pump (with YGVI control) - Single Stage Furnace (S-ECM)
ID MODELS
Y1
First Stage Compressor
Y1
First Stage Compressor
Y1
Single Stage
Compressor
Change “FFuel” jumper
on the heat pump control
to “ON”
Jumper 1 must be
set to “HEAT PUMP”
Jumper 2 must be
set to “O”
Jumper 3 must be
set to “GAS”
Setup Step 50 “Dual
Fuel” must be set
“External”
Suggestion: Set setup
step 26 “2nd Stage
Deadband” and step 29
“Minutes Between 1st
and 2nd” to 0.