Johnson Controls Unitary Products
MENU NOTES:
Discharge Pressure, Liquid Temperature, Suction Pressure, Suction
Temperature, Calculated Superheat, and Calculated Subcool. On the
high gauge display, the control shall toggle at a rate of 10 seconds
between the Liquid Temperature and the Subcool calculated value. On
the low gauge display, the control shall toggle at a rate of 10 seconds
between the Suction Temperature and the Superheat calculated value.
Time out period: While in the Menu Structure if the display does not
sense a navigational response within 5 minutes, the outdoor display will
return to General Display Operation.
Door Switch: If the outdoor display is in the Menu Structure and the
door switch is de-activated, the system will de-energizing the outdoor
screen. Upon re-energizing the outdoor screen, the display will return to
the General Display Operation.
Saved Configuration/Selection: The system will save all individual con-
figuration selections made on the Outdoor Display. Upon returning to a
previously saved configuration the system shall display the previously
saved configuration setting(s). Not the Default setting(s), unless the
saved selection was in fact the default selection.
Operational Mode: The system will display (Inverter profile and revers-
ing valve dependent) unit tonnage when the user selects Operational
Mode (AC).
TABLE 6:
Outdoor Display Menu Structure
MAIN LAYER
SECOND LAYER
THIRD LAYER
BASE LAYER
EQUIPMENT STATUS
COMMANDED
COMPRESSOR (RPM)
OD FAN (RPM)
ID EEV (SP)
ID FAN (CFM)
CURRENT
COMPRESSOR (RPM)
OD FAN (RPM)
ID EEV (SP)
ID FAN (CFM)
INPUT CURRENT (AMPS)
INPUT VOLTAGE (VOLTS)
INPUT WATTS (WATTS)
CONFIGURATIONS
DEMAND RESPONSE
OFF (Default)
NORMALY OPEN RELAY
NORMALY CLOSED RELAY
INVERTER REPAIR PART
System will first determine Unit Type (Reversing Valve Presence) and Unit Tonnage
(Inverter Configuration) and will walk the user through the operation, per inverter part num-
ber.
2-TON
3-TON
4-TON
5-TON
SOFT JUMPERS
COMFORT - EFFICIENCY
EFFICIENCY (Default)
COMFORT
MODES
FAULT MODE
CURRENT SYSTEM FAULTS
STORED SYSTEM FAULTS
CLEAR FAULT LOG
TEST MODE
BYPASS ASCD TIMER
OPERATIONAL MODE (AC)
System will display Unit Type (Reversing Valve Presence) and Unit Tonnage (Inverter Con-
figuration)
CHARGE VERIFICATION
System determines Unit Tonnage (Inverter Configuration) and will walk the user through
the operation.