10. Troubleshooting
10.1
Indoor unit error code explanation:
Malfunction
Error Code
Timer Lamp
Operation Lamp
(flashes)
Indoor EEPROM malfunction
E0
X
1
Communication malfunction between indoor and outdoor units
E1
X
2
Indoor fan speed has been out of control
E3
X
4
Open or short circuit of T1 temperature sensor
E4
X
5
Open or short circuit of T2 temperature sensor
E5
X
6
Water level alarm
EE
X
8
Overcurrent protection (For some units)
F0
O
1
Open or short circuit of T4 temperature sensor
F1
O
2
Open or short circuit of T3 temperature sensor
F2
O
3
Open or short circuit of T5 temperature sensor
F3
O
4
Outdoor EEPROM malfunction (For some units)
F4
O
5
Outdoor fan speed is out of control
F5
O
6
Open or short circuit of T2B temperature sensor (For free-match indoor
units)
F6
O
7
Communication error between auto-lifting panel and slim cassette (For
slim cassette with auto-lifting panel)
F7
O
8
Auto-lifting panel is faulty (For slim cassette with auto-lifting panel)
F8
O
9
Auto-lifting panel is not closed (For slim cassette with auto-lifting panel)
F9
O
10
IPM module malfunction
P0
☆
1
Over voltage or over low voltage protection
P1
☆
2
Too low ambient temperature protection
P3
☆
4
Error rotor position protection of compressor
P4
☆
5
Mode conflict
P5( for
Premier
&Oasis
models)
--(for other
models)
☆
6
Low pressure protection of compressor
P6
☆
7
O (on) X(off)
☆
(flash at 2Hz)
10.2
Outdoor unit error code explanation:
Display
LED STATUS
E0
Outdoor EEPROM malfunction
E2
Indoor / outdoor units communication error
E3
Communication malfunction between IPM board and outdoor main board
E4
Open or short circuit of outdoor unit temperature sensor
E5
Voltage protection
E8
Outdoor fan speed has been out of control
Summary of Contents for YU2E14YEEBMHO-X
Page 8: ...7 5 Wiring diagram YU2E14YEEBMHO X YU2E18YEEBMHO X...
Page 10: ...9...
Page 11: ...10 YU4E28YEEBMHO X YU4E36YEEBMHO X...
Page 12: ...11 YU5E42YEEBMHO X...
Page 34: ...33 10 3 1 2 Indoor outdoor units communication error...
Page 39: ...38 10 3 1 4 Open or short circuit of temperature sensor 10 3 1 5 Full water malfunction...
Page 42: ...41 10 3 3 2 Communication malfunction between IPM board and outdoor main board ODU E3...
Page 45: ...44 10 3 3 5 High pressure protection ODU P1 ForYU4E28YEEBMHO X YU4E36YEEBMHO X YU5E42YEEBMHO X...
Page 47: ...46 10 3 3 7 Current protection of compressor ODU P3...
Page 48: ...47 10 3 3 8 Temperature protection of compressor discharge ODU P4...