Electrical Data
Model
Rated
Voltage
Voltage
Min/Max
Compressor
Fan
Motor
FLA
Total
Unit
FLA
Min
Circ
Amp
Max
Fuse/
HACR
MCC
RLA
LRA
09
115/60/1
104/127
12.5
8.0
50.0
4.25
12.3
14.3
20
208-230/60/1
187/253
6.4
4.1
21.0
2.6
6.7
7.7
10/15
265/60/1
238/292
6.7
4.3
22.0
2.5
6.8
7.9
10/15
12
115/60/1
104/127
14.8
9.5
50.0
4.25
13.8
16.1
25
208-230/60/1
187/253
7.7
4.9
25.0
2.6
7.5
8.8
10/15
265/60/1
238/292
7.0
4.5
22.0
2.5
7.0
8.1
10/15
15
208-230/60/1
187/253
9.2
5.9
29.0
2.6
8.5
10.0
15
265/60/1
238/292
7.8
5.0
28.0
2.5
7.5
8.8
10/15
18
208-230/60/1
187/253
10.4
6.7
33.5
2.6
9.3
10.9
15
265/60/1
238/292
8.7
5.6
28.0
2.5
8.1
9.5
15