7
LX COMPACT SERIES INSTALLATION MANUAL
Vertical Dimensional Data cont.
Vertical Models
LL
015-018
15.8 [40.1]
024-030
18.8 [47.8]
036
15.3 [38.9]
042-048
13.8 [35.1]
060
14.3 [36.3]
070
14.3 [36.3]
Dimensions in inches [cm]
* Models 006-012 - Externally Mounted Disconnect
**UBV-041 - Disconnect not available
Vertical Disconnect
When using disconnect, do not use dimension L from the standard
vertical dimensional data. Use dimension LL from the vertical
disconnect dimensional data.
Vertical
Models
Overall Cabinet
Water Connections
Electrical Knockouts
6
7
8
1
2
5
J
K
L
A
B
C
D
E
H
Loop
1/2” cond
1/2” cond
1” cond
M
Width
Depth
Height*
In
Out
Condensate
Water FPT
Low
Voltage
Low
Voltage
Power Sup-
ply
Filter Rack
Width
006-012
in.
19.2
19.2
24.2
2.6
5.6
8.8
1/2”
7.4
3.4
5.4
2.2
cm.
48.8
48.8
61.5
6.6
14.2
22.4
12.7 mm
18.8
8.6
13.7
5.6
015-018
in.
22.5
22.2
30.2
2.6
7.6
10.8
3/4”
9.4
5.4
7.4
2.2
cm.
57.2
56.4
76.7
6.6
19.3
27.4
19.1 mm
23.9
13.7
18.8
5.6
024-030
in.
22.5
22.2
36.2
2.6
7.6
10.8
3/4”
9.4
5.4
7.4
2.2
cm.
57.2
56.4
91.9
6.6
19.3
27.4
19.1 mm
23.9
13.7
18.8
5.6
036
in.
22.5
26.2
40.2
2.6
7.6
10.8
3/4”
10.1
6.1
8.1
2.2
cm.
57.2
66.5
102.1
6.6
19.3
27.4
19.1 mm
25.7
15.5
20.6
5.6
041
in.
21.5
21.5
40.2
2.6
7.6
10.8
3/4”
9.4
5.4
7.4
1.2
cm.
54.6
54.6
102.1
6.6
19.3
27.4
19.1 mm
23.9
13.7
18.8
3.0
042-048
in.
22.5
26.2
44.2
2.6
7.6
10.8
3/4”
10.1
6.1
8.1
2.2
cm.
57.2
66.5
112.3
6.6
19.3
27.4
19.1 mm
25.7
15.5
20.6
5.6
060
in.
25.5
31.2
44.2
2.6
7.6
10.8
1”
10.1
6.1
8.1
2.2
cm.
64.8
79.2
112.3
6.6
19.3
27.4
25.4 mm
25.7
15.5
20.6
5.6
070
in.
25.5
31.2
48.2
2.6
7.6
10.8
1”
10.1
6.1
8.1
2.2
cm.
64.8
79.2
122.4
6.6
19.3
27.4
25.4 mm
25.7
15.5
20.6
5.6
Vertical
Models
Discharge Connection
duct fl ange installed (±0.10 in)
**Return Connection
using deluxe fi lter rack (±0.10 in)
N
P
Q
R
S
T
U
V
W
Supply Width
Supply Depth
Return Depth
Return Height
006-012
in.
10.0
10.0
4.6
4.4
7.8
2.4
14.3
10.1
2.0
cm.
25.4
25.4
11.7
11.2
19.8
6.1
36.3
25.7
5.1
015-018
in.
14.0
14.0
4.1
4.3
7.7
2.1
18.1
14.0
2.0
cm.
35.6
35.6
10.4
10.9
19.6
5.3
46.0
35.6
5.1
024-030
in.
14.0
14.0
4.1
4.3
7.7
2.1
18.1
20.0
2.0
cm.
35.6
35.6
10.4
10.9
19.6
5.3
46.0
50.8
5.1
036
in.
14.0
14.0
6.1
4.5
7.7
2.1
22.1
22.1
2.0
cm.
35.6
35.6
15.5
11.4
19.6
5.3
56.1
56.1
5.1
041
in.
14.0
14.0
3.8
3.5
6.7
0.6
20.2
28.0
0.6
cm.
35.6
35.6
9.7
8.9
17.0
1.5
51.3
71.1
1.5
042-048
in.
18.0
18.0
4.1
2.1
3.9
2.1
22.1
26.1
2.0
cm.
45.7
45.7
10.4
5.3
9.9
5.3
56.1
66.3
5.1
060
in.
18.0
18.0
6.6
4.6
6.3
1.6
28.1
26.0
2.0
cm.
45.7
45.7
16.8
11.7
16.0
4.1
71.4
66.0
5.1
070
in.
18.0
18.0
6.6
4.6
6.3
1.6
28.1
30.0
2.0
cm.
45.7
45.7
16.8
11.7
16.0
4.1
71.4
76.2
5.1
Condensate is 3/4” PVC female glue socket and is switchable from side to front. 10/15/15
*Discharge fl ange is fi eld installed and extends 1” (25.4 mm) from top of cabinet.
**Vertical units shipped with standard 2” (fi eld adjustable to 1”) open application fi lter rack extending 2.2” from unit and is not suitable for duct connection.
For ductable return connection applications, order the deluxe 2” (fi eld adjustable to 1”) duct collar/fi lter rack which extends 3.25