background image

1C750W2 (1.5kW) User Manual 

General 

Your Eco Heat heater has been designed using the 

latest in technology. With normal care and 
maintenance, your heater will provide years of 

satisfactory performance.

 

This heater has been designed for use on 230 V 

circuits. Do not use it in areas where a standard 

voltage of 230 V is not provided. 

If, after reviewing this guide, you require additional 

information or assistance please contact Eco Heat 

Equipment at

 

[email protected], +27 (0)861 999 

887, or www.ecoheat.co.za. 

 

 
Technical Specifications 

 

Power consumption: 1500W 

 

Dimensions: 124.7cm(L) x 5.3cm*(W) x 

13.6cm(H)   (* excludes mounting bracket) 

 

Indoor heat coverage area: 

±

 15 m

²

 to 20 m

2

 

 

Power density: 

±

 75W per m

²

 to 100W per m

2

 

 

Weight: 

±

 3.5 kg 

 

Minimum cord length:  2 m 

 

Electrical Classification: class I device 

 

Input: 230 V, 50 Hz 

 
Safety 

Any use not recommended by the manufacturer 
may cause fire, electrical shock or injury to persons. 

 

This heater is hot when in use, to avoid burns, 

do not let bare skin touch it. 

 

Keep combustible materials such as furniture, 

pillows, bedding, clothes and curtains at least  
1 m away from the heater. 

 

Do not cover or hang anything over the heater 

as it may combust.

 

 

 

Fire risk exists if heater is covered or positioned 

incorrectly. 

 

Never leave the heater unattended while in 

use. 

 

Always turn the heater off when it is not in use. 

 

Avoid using an extension cord as this may 
overheat and cause a risk of a fire. If an 

extension cord must be used, make sure it is 

rated for 10 A. 

 

To move the heater, switch heater off and let it 

cool for at least 15 minutes. 

 

Never locate the heater where it might fall into 

a bathtub or other water container. 

 

If the heater is to be used in a bathroom, the 

heater is to be installed so that switches and 

other controls cannot be touched by a person 
in the bath or shower.  

 

Do not insert foreign objects past the heaters 

grid. The elements are extremely hot and the 

risk of electrical shock under fault conditions 

exists. 

 

Do not use the heater in rooms with explosive 

gas (e.g. petrol) or while using flammable 

substances. 

 

Keep the mains cord at a safe distance from 

the main body of the heater. 

 

Do not run the cord of the heater under 

carpeting. Do not cover the cord with throw 

rugs, runners or other floor coverings. Arrange 

the cord away from traffic areas where it will 

not be tripped over. 

 

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they 
have been given supervision or instruction 

concerning use of the appliance by a person 

responsible for their safety.  

 

Children should be supervised to ensure that 

they do not play with the appliance.  

 

If the supply cord is damaged, it must be 

replaced by the manufacturer, its service 

agent or similarly qualified persons in order to 

avoid a hazard.  

 

Mounting/Installation 

Your box should contain the following items: 

 

One 1C750W2 heater 

 

Two bolts 

 

Four ring washers 

 

Two wall mounting brackets 

 

Two spring washers 

 

Two nuts 

Step 1 – Bracket assembly 

Assemble the bracket in the following order: 

a.

 

Bolt, ring washer, heater bracket, wall mounting 

bracket, ring washer, spring washer, nut. 

 

 

 

Step 2 – Heater positioning 

a.

 

Install the heater 1.8 m to 2.3 m above the floor. 

b.

 

A minimum unobstructed distance (minimum 

clearance) of 200 mm must be maintained 

between the heater and any object that may 

affect the operation or safety of the heater.  

c.

 

Mount/place the heater where it is out of reach 

of small children. 

Step 3 – Wall Mounting 

a.

 

The wall mounting structure and the anchoring 

provisions must be of sufficient strength to 
support the weight of the heater, elements and 

all accessories. 

b.

 

Ensure the heater is mounted with the ‘This side 

up’ sticker pointing up. 

c.

 

Attach the heater to the wall with four 
screws/bolts using the holes provided in the wall 

mounting bracket. 

 

 
Electrical Installation

 

All wiring must be done in accordance with 

National and Local Electrical Codes and 

Standards. 

The heater operates from a normal 15 A 3 pin 
socket outlet on earth leakage on a 230 V system, 

or connects directly on a 230 V, 2-pole isolator on 

earth leakage. 

 
Operation 

The heater will automatically start working once it 

has been connected to the correct 230 V power 

source. The LED light will glow to indicate the 

heater is on. 
Radiant heat will be felt in front of the reflector 

after about 30 seconds, and continue to increase 

in intensity for 3-4 minutes. 

 
Infrared Radiation  

The heater uses infrared radiation to heat objects. 

Do not stare into the heater for prolonged periods 

at a short distance without adequate eye 
protection as this may cause damage to the eyes. 

Take adequate precautions to safeguard against 

excessive exposure, such as moving further away 

from the heater or switching the heater off when 

heat becomes uncomfortable. 

 

 

Maintenance 

The heater contains no user serviceable parts. 

The elements should last in excess of 10 000 hours. 

If the heater has not been in use for a while, ensure 

it is disconnected from the power source. Dust the 

elements with a soft duster to remove excess dust. 

This should prevent odors after first use.  

 
Cleaning 

Clean the outside of the heater only when it is 

disconnected from the power source and cool. If it 

has been in operation, switch off and wait for at 

least 15 minutes. 

 

Carefully wipe the exterior of the heater with a soft 

damp cloth and dry thoroughly with a dry cloth. Do 
not use harsh or abrasive cleaners to clean your 

heater, as these may damage the surface. 

Do not let the inside of the heater get wet as this 

may cause a risk of electrical shock. 

 
Recycling  

Please recycle all packaging material that came 

with the heater.  
If you are replacing an old heater, please go to 

www.ewasa.org or contact Eco Heat for 

information on responsible disposal or recycling.  

 
Warranty 

The heater has a one year warranty after the date 

of the original purchase. Please keep your original 

receipt, as this will be required for any claims under 

this warranty.  
The warranty covers workmanship, materials and is 

limited to the purchase price of the heater.

 

The warranty does not cover:  

 

damage from misuse,  

 

neglect or abuse,  

 

products that have been modified in any way,  

 

shipping and handling cost associated with the 

replacement of the product. 

For more information, view the Returns / Refund 

Policy at www.ecoheat.co.za/terms.php. 

 

Trouble shooting 

If the heater is plugged into a live 230 V power 

source and no heat is felt after 3-4 minutes the 

heater may be faulty. 
Try ONE of the following: 

a.

 

Ensure the power source is working. 

b.

 

Unplug the heater and have a certified 

electrician test the electrical circuitry. If the 

circuitry is in working order, the elements might 

need replacement. 

 
Contact Eco Heat Equipment for a 

replacement element. 

 

Replacement parts 

Replacement elements can be ordered at 

www.ecoheat.co.za. 

 

 
Due to minor improvements in design or otherwise, the 
product you buy may differ from the one shown in this 
leaflet. For more information or advice on this or any 
other Eco Heat Equipment products, visit 
www.ecoheat.co.za or phone +27 (0)861 999 887. 

 

!