(11) For Left Side Piping
Perform the following piping connection work.
(a) It is recommended that the piping connection work be performed
by 2 people: one supports the indoor unit and the other performs
the piping connection.
(b) Correctly position piping before installing the indoor unit to the wall. For left rear-side piping
connections, refer to Section 5.2.6.
Take care not to uncouple the indoor unit from the
mounting plate.
● Do not apply excessive force to the flare nut when tightening. If applied, the flare nut may crack
due to stress fracture and refrigerant leakage may occur. Use the correct torque specifications.
● Make sure that a refrigerant leak test is performed. Refrigerant (Fluorocarbon) for this unit is non-
flammable, non-toxic, and odorless. If the refrigerant should somehow escape and come into
contact with flame, toxic gas
will
form. This gas is heavier than air and settles near floor areas and
spreads where it can cause suffocation to those nearby.