036-21030-003 Rev. B (0203)
20
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
E4FD036S06, E4FD036S25, 46
EVAPORATOR COIL MODEL NO
F2RP/F2FP036
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1100
1200
1300
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
60
42.8
3.34
3.85
43.2
3.28
3.97
42.5
3.25
3.94
70
40.3
3.52
3.45
41.4
3.47
3.59
41.4
3.46
3.60
80
38.5
3.68
3.16
40.2
3.65
3.32
40.9
3.66
3.37
47
60
36.6
3.09
3.48
37.0
3.07
3.54
36.1
3.06
3.46
70
34.4
3.23
3.12
35.2
3.23
3.20
35.1
3.23
3.18
80
32.6
3.36
2.85
33.9
3.38
2.95
34.5
3.40
2.98
40
60
32.7
2.97
3.20
33.7
2.98
3.29
34.5
2.99
3.35
70
31.0
3.09
2.92
31.9
3.10
2.99
32.8
3.12
3.06
80
29.3
3.22
2.65
30.2
3.24
2.71
31.2
3.26
2.78
30
60
27.5
2.80
2.84
28.9
2.84
2.94
29.0
2.86
2.92
70
25.8
2.87
2.60
27.2
2.92
2.69
27.5
2.94
2.70
80
23.6
2.97
2.30
25.1
3.03
2.39
25.6
3.06
2.42
17
60
22.0
2.55
2.53
22.5
2.60
2.54
22.6
2.63
2.52
70
20.3
2.62
2.27
21.0
2.68
2.30
21.3
2.71
2.30
80
18.5
2.68
2.03
19.4
2.75
2.08
19.8
2.78
2.10
10
60
18.4
2.44
2.28
19.2
2.50
2.31
19.5
2.54
2.31
70
16.7
2.48
2.03
17.7
2.55
2.09
18.0
2.59
2.10
80
15.0
2.51
1.80
16.1
2.59
1.88
16.5
2.62
1.89
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
F2RP/F2FP042
1.00
1.00
1.00
G2FD036(S,H)17
1.00
1.00
1.00
G2FD036(S,H)21
1.00
1.00
1.00
G2FD042(S,H)21
0.99
0.99
1.00
G2FD046(S,H)17
0.99
0.99
1.00
G1HD036
1.03
1.01
1.02
G1UA048S21
0.99
0.99
1.00
G1FA048S21
0.99
0.99
1.00