036-21030-003 Rev. B (0203)

6

Unitary Products Group

*

Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.

**

Refer to Quick Selection Chart for specific furnace match-up.

E4FD048S25,46

1400
1800

21,24

G1FA048S21

1600

46.0

34.0

10.70

-

9.45

21,24

G1FA060S21,24

1600

47.0

34.0

10.80

-

9.60

21,24

G1UA048S21

1600

46.0

34.0

10.70

-

9.45

21,24

G1UA060S21,24

1600

47.0

34.8

10.80

-

9.60

-

G1HD048

1600

45.0

33.3

10.50

-

9.40

-

G1HD060

1620

46.5

34.4

10.70

-

9.60

21,24

G2FD048(S,H)21,24

1600

45.5

33.7

10.50

-

9.40

24

G2FD060(S,H)24

1600

47.0

34.8

10.80

-

9.65

E4FD060S06

1600
2100

21,24

G1FA060S21,24

1800

58.5

43.3

10.50

-

9.90

21,24

G1UA060S21,24

1800

58.5

43.3

10.50

-

9.90

-

G1HD060

1800

57.0

42.2

10.50

-

9.20

24

G2FD060S24

1800

59.0

43.7

11.00

-

9.90

E4FD060S25,46

1600
2100

21,24

G1FA060S21,24

1800

58.5

43.3

10.50

-

9.90

21,24

G1UA060S21,24

1800

58.5

43.3

10.50

-

9.90

-

G1HD060

1800

57.0

42.2

10.50

-

9.20

24

G2FD060(S,H)24

1800

59.0

43.7

11.00

-

9.90

1. TXV = Use 1TV700 Series Kit.

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)

UNIT MODEL

FURNACE**

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED 

CFM

NET MBH

SEER

W/O TXV

1

SEER + TXV

1

EER

TOTAL

SENS.

HEATING PERFORMANCE - With Air Handler and Multi-Position Coils

UNIT

MODEL

COIL

MODEL

1

ARI HEATING

2

OUTDOOR TEMP

3

47° F

17° F

HSPF

-3°F

7°F

17° F

27°F

37°F

47°F

57°F

MBH COP MBH COP STD VS MBH KW MBH KW MBH KW MBH MBH MBH KW MBH KW MBH KW

1 AND 3 PHASE HP / AIR HANDLERS & COILS

E4FD018

F2RP/F2FP018

17.6 3.00

10

2.00 7.10 --

4.4 1.09 7.2

1.1

10

1.25 12.4

1.3

15

1.42 17.6 1.53

21

1.75

F2RP/F2FP024

17.8 3.10

10

2.00 7.10 --

4.8 1.05 7.4 1.09

10

1.25 12.6 1.31 15.6 1.4 17.8 1.5 21.2 1.73

G2FD024(S,H)14, 17

18

3.06

9.9

2.00 7.10 7.2

5

1.02 7.6

1.1

9.9 1.23 12.8 1.32 15.6 1.38

18

1.52

22

1.72

E4FD024

F2RP/F2FP024

22.4 3.10 12.5 2.00 7.35 --

6.1

1.5

9.3

1.6 12.5 1.75 15.6 1.92 18.8 2.02 22.4 2.13 27.1 2.23

F2RP/F2FP030

22.8 3.20 12.8 2.10 7.40 --

6.3 1.55 9.4 1.68 12.8 1.68

16

1.9

19

2

22.8 2.14 27.7 2.3

G2FD024(S,H)14, 17

22.4 3.10 12.2 2.00 7.60 7.7 6.3

1.5

9.3

1.5 12.2 1.7

16

1.89 19.2 2.05 22.4 2.12

27

2.4

G2FD030(S,H)17

22.6 3.10 12.4 2.00 7.10 7.2 6.5

1.4

9.6 1.46 12.4 1.7

16

1.92

19

2.07 22.6 2.14

28

2.33

G2FD035(S,H)14

22.4 3.10 12.4 2.00 7.10 --

6.6

1.5

9.8

1.6 12.4 1.7 16.2

1.9

19.2 2.06 22.4 2.15

28

2.3

E4FD030

F2RP/F2FP030

29

3.20

17

2.30 7.60 --

10.4

2

13.8 2.1

17

2.23 21.2 2.35 24.8 2.48

29

2.58 34.2 2.68

F2RP/F2FP036

28.4 3.20 17.4 2.30 7.50 --

10.2 1.95 13.6 2.11 17.4 2.22

22

2.37 24.8 2.5 28.4 2.57 34.6 2.69

G2FD030(S,H)17

29.2 3.20

17

2.30 7.60 7.8 10.4

2

13.8 2.18

17

2.21 21.8

2.4

25

2.6 29.2 2.58 34.2 3.7

G2FD035(S,H)14

29.2 3.20

17

2.30 7.60 --

10.7 1.98

14

2.15

17

2.23

24

2.42 25.8 2.48 29.2 2.58 34.4 2.65

G2FD036(S,H)17, 21

29.2 3.20 17.4 2.30 7.60 7.7 10.8

2

14.2 2.11 17.4 2.22

24

2.4

25.6 2.48 29.2 2.54 34.6 2.67

E4FD036

F2RP/F2FP036

35.2 3.20

21

2.30 7.50 --

10.8 2.5 15.4 2.63

21

2.8 24.8 2.95 28.4

3

35.2 3.26

43

3.47

F2RP/F2FP042

35.2 3.20

20

2.10 7.50 --

10.8 2.5 15.6 2.6

20

2.6

25

2.94 28.6

3

35.2 3.2 43.2 3.4

G2FD042(S,H)21

35

3.20

20

2.10 7.40 7.6 10.8 2.2 15.4 2.62

20

2.6

25

2.76 28.8 2.95

35

3.2 43.2 3.45

G2FD046(S,H)17

35

3.20

20

2.10 7.40 7.6 10.8 2.2 15.8 2.6

20

2.7 25.2 2.76 28.8 2.95

35

3.2

44

3.46

G2FD036(S,H)17, 21

35.2 3.20

21

2.30 7.50 7.6 10.6 2.5 15.4 2.64

21

2.6

25

2.8

28.6 2.98 35.2 3.2

43

3.4

E4FD042

F2RP/F2FP042

39.5 3.20 22.6 2.20 7.4

-

11.7 2.50 17.2 2.76 22.6 3.00 28.0 3.26 33.9 3.50 39.5 3.62 48.7 4.01

F2FP048

40.5 3.30 23.8 2.28 7.5

-

13.1 2.60 18.5 2.84 23.8 3.10 29.1 3.28 35.0 3.50 40.5 3.60 49.8 4.00

G2FD042(S,H)21

39.0 3.24 23.2

2.2

7.4

-

13.4 2.81 18.3 2.95 23.2 3.09 28.1 3.23 33.6 3.39 39.0 3.53 46.7 3.76

G2FD046(S,H)17

39.0 3.28 23.2 2.20 7.4

-

13.0 2.80 18.1 2.92 23.2 3.10 28.3 3.26 33.8 3.40 39.0 3.46 47.8 3.80

G2FD048(S,H)21,24

39.5 3.40 23.4 2.28 7.4 7.5 13.1 2.50 18.2 2.67 23.4 2.90 28.6 3.04 34.2 3.20 39.5 3.31 48.6 3.60

E4FD048

F2FP048

47.0 3.30 28.0

2.3

7.8

-

15.7 3.16 21.8 3.36 28.0 3.57 34.2 3.77 40.9 4.00 47.0 4.17 56.1 4.50

G2FD048(S,H)21,24

47.0 3.50 28.0 2.32 8.0 8.0 16.1 3.30 22.1 3.40 28.0 3.50 33.9 3.67 40.7 3.80 47.0 3.96 54.8 4.20

G2FD060(S,H)24

47.0 3.46 28.0 2.32 8.0 8.0 16.1 3.3 22.0 3.41 28.0 3.50 34.0 3.67 40.7 3.80 47.0 3.94 54.9 4.10

E4FD060

F2FP060

61

3.30

39

2.40 8.20 --

21.4 4.5 30.1 4.6

39

4.75

43

4.9

52.1 5.1

61

5.3

63

3.47

F2FV060

60

3.30

39

2.40 8.20 --

21.1 4.3

31

4.7

39

4.8 43.2 4.91 52.3 5.09

60

5.25 63.2 3.4

G2FD060(S,H)24

60

3.40

39

2.40 8.50 8.5 21.1 4.4 26.2 4.6

38

4.7

43

4.85 51.8 5.1

60

5.3

63

3.45

1. Rated CFM same as for cooling.
2. Heating performance and efficiency is the same for TXV application. Heating MBH based on 70° DB entering indoor air, 72% RH outdoor air with 25 

feet of interconnecting piping and no supplemental electric heat operation. 

3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.

Summary of Contents for STELLAR 2000 EFD Series

Page 1: ...damage by a polymer mesh applied between the coil face and a PVC coated steel coil guard DEFROST CONTROL Time Temperature defrost control provides field selectable time periods between defrost cycles...

Page 2: ...8 E4FD060 25 46 Unit Supply Voltage 208 230 3 60 460 3 60 Normal Voltage Range 1 187 TO 253 432 TO 504 Minimum Circuit Ampacity 15 2 20 1 25 0 8 0 9 0 11 4 Max Overcurrent Device Amps 2 25 30 40 15 15...

Page 3: ...FACTORY CHARGE LBS OZ 4 11 4 12 5 3 5 11 7 6 7 6 9 5 ID Orifice included w Instruction Package 53 61 67 75 78 81 84 87 93 INDOOR COIL COIL ORIFICE1 REQUIRED SYSTEM ORIFICE ADDITIONAL CHARGE OZ G1FA G1...

Page 4: ...S H 21 1225 36 2 27 2 11 20 10 00 E4FD042 N1VSC16 5 7 5 10 15 20 21 G2FD048 S H 21 1425 42 0 31 1 11 00 10 00 E4FD048 N1VSC16 5 7 5 10 15 20 21 G2FD048 S H 21 1600 46 0 34 0 11 00 10 00 N1VSD20 7 5 10...

Page 5: ...50 9 30 17 G2FD036 S H 17 1025 29 4 22 1 11 00 9 40 21 G2FD036 S H 21 1025 29 4 22 1 11 00 9 40 E4FD036S06 1050 1350 21 24 G1FA048S21 1250 35 6 26 7 10 30 9 20 21 24 G1UA048S21 1250 35 6 26 7 10 30 9...

Page 6: ...8 2 1 17 2 23 21 2 2 35 24 8 2 48 29 2 58 34 2 2 68 F2RP F2FP036 28 4 3 20 17 4 2 30 7 50 10 2 1 95 13 6 2 11 17 4 2 22 22 2 37 24 8 2 5 28 4 2 57 34 6 2 69 G2FD030 S H 17 29 2 3 20 17 2 30 7 60 7 8 1...

Page 7: ...6 4 3 25 44 6 3 56 G1FA048S21 35 0 3 2 20 0 2 10 7 4 8 9 1 93 14 7 2 21 20 4 2 49 26 1 2 77 30 0 2 97 37 0 3 29 44 8 3 62 G1UA048S21 35 0 3 2 20 0 2 10 7 4 8 9 1 93 14 7 2 21 20 4 2 49 26 1 2 77 30 0...

Page 8: ...f supplemental electric heat Room Thermostats A wide selection of matching thermo stats is available to provide features required for any installa tion 2H 1C manual change over electronic non programm...

Page 9: ...OR UNIT OUTDOOR UNIT POWER WIRING 208 230 1 60 CONTACTOR GND SCREW T2 T1 L2 L1 M CIRCUIT BREAKER4 POWER WIRING 24V CONTROL WIRING NEC CLASS 2 GND LUG LOW VOLTAGE TERMINAL BLOCK IN AIR HANDLER WITH ELE...

Page 10: ...15 9 14 6 19 5 17 8 16 0 14 8 19 7 17 9 16 1 14 9 S C 13 0 12 9 13 0 13 2 13 4 13 4 13 4 13 6 13 8 13 8 13 8 14 0 K W 1 70 1 68 1 65 1 62 1 72 1 70 1 67 1 64 1 76 1 75 1 72 1 69 105 T C 17 6 15 7 14...

Page 11: ...17 4 17 4 17 5 17 8 K W 2 24 2 18 2 12 2 05 2 26 2 20 2 13 2 06 2 30 2 24 2 17 2 11 105 T C 22 5 20 5 18 4 17 0 22 6 20 6 18 6 17 0 22 7 20 7 18 6 17 1 S C 16 1 16 0 16 0 16 3 16 5 16 4 16 5 16 5 16 9...

Page 12: ...0 22 4 22 7 22 7 22 9 23 2 K W 2 84 2 75 2 65 2 56 2 89 2 80 2 70 2 62 2 93 2 84 2 74 2 67 105 T C 28 9 26 4 23 9 21 9 29 2 26 7 24 5 22 2 29 4 26 9 24 8 22 9 S C 20 4 20 3 20 6 20 8 21 4 21 3 22 0 2...

Page 13: ...3 35 3 25 3 60 3 50 3 40 3 30 3 70 3 60 3 50 3 40 105 T C 33 2 30 6 27 9 25 5 33 4 30 8 28 1 26 0 33 7 31 0 28 4 26 4 S C 24 0 24 0 24 2 24 1 25 0 25 1 25 2 25 3 26 1 26 1 26 3 25 7 K W 3 78 3 68 3 56...

Page 14: ...5 40 5 36 7 33 2 44 6 40 6 37 0 33 6 S C 28 9 28 9 29 2 29 2 30 0 30 0 30 3 30 1 30 8 30 8 31 2 31 1 K W 42 00 4 25 4 08 3 93 4 47 4 31 4 14 3 99 4 55 4 39 4 22 4 08 105 T C 41 3 37 6 34 0 30 8 41 5 3...

Page 15: ...3 33 8 34 0 34 7 34 8 35 4 35 6 36 2 36 2 K W 4 84 4 77 4 71 4 63 4 95 4 88 4 80 4 73 5 18 5 10 5 02 4 95 105 T C 45 8 42 3 38 9 35 7 46 3 42 6 39 3 36 2 46 4 43 0 39 6 37 4 S C 31 2 31 4 32 0 32 1 3...

Page 16: ...5 46 5 36 5 68 5 58 5 48 5 39 5 71 5 59 5 49 5 40 95 T C 62 0 56 9 51 8 47 3 62 6 57 5 52 4 48 0 63 1 58 0 53 0 48 4 S C 41 2 41 4 41 8 42 0 42 9 43 1 43 6 44 0 44 7 44 8 45 5 45 5 K W 6 09 5 98 5 87...

Page 17: ...25 16 8 1 61 3 03 17 5 1 51 3 36 70 13 7 1 50 2 66 15 8 1 66 2 77 15 7 1 56 2 92 80 12 7 2 00 1 84 14 7 1 72 2 50 13 9 1 89 2 14 30 60 14 0 1 52 2 67 14 4 1 53 2 72 14 1 1 40 2 91 70 12 8 1 56 2 37 13...

Page 18: ...7 3 39 70 17 4 1 86 2 73 20 1 2 05 2 84 19 9 1 93 3 00 80 16 5 2 56 1 88 19 2 2 20 2 54 18 1 2 42 2 18 30 60 17 2 1 89 2 63 17 7 1 91 2 68 17 3 1 75 2 86 70 16 1 1 93 2 41 16 8 1 96 2 48 16 9 1 82 2 6...

Page 19: ...3 22 27 6 2 46 3 27 27 8 2 48 3 26 70 25 3 2 51 2 93 26 2 2 55 2 99 26 5 2 57 2 99 80 23 9 2 62 2 65 24 8 2 64 2 73 25 2 2 67 2 74 30 60 23 2 2 30 2 91 24 1 2 32 2 99 24 5 2 35 3 00 70 21 2 2 35 2 61...

Page 20: ...3 7 2 98 3 29 34 5 2 99 3 35 70 31 0 3 09 2 92 31 9 3 10 2 99 32 8 3 12 3 06 80 29 3 3 22 2 65 30 2 3 24 2 71 31 2 3 26 2 78 30 60 27 5 2 80 2 84 28 9 2 84 2 94 29 0 2 86 2 92 70 25 8 2 87 2 60 27 2 2...

Page 21: ...2 3 23 3 37 37 1 3 22 3 38 70 36 0 3 56 2 97 35 6 3 51 2 97 35 6 3 49 2 99 80 35 2 3 91 2 64 34 9 3 85 2 66 35 1 3 82 2 69 30 60 31 6 3 07 3 02 31 6 3 05 3 04 31 6 3 05 3 04 70 30 3 3 38 2 63 29 9 3...

Page 22: ...27 3 35 42 6 3 99 3 13 43 0 3 64 3 47 70 37 0 3 68 2 94 42 6 4 07 3 07 42 2 3 82 3 24 80 36 2 5 36 1 98 42 1 4 62 2 67 39 7 5 06 2 30 30 60 35 8 3 69 2 85 36 8 3 72 2 90 37 7 3 57 3 10 70 34 8 3 83 2...

Page 23: ...2 89 59 7 6 08 2 88 40 60 55 4 4 98 3 24 56 0 5 01 3 27 53 8 4 95 3 17 70 56 0 5 37 3 04 56 0 5 32 3 07 55 5 5 29 3 06 80 55 7 6 00 2 71 55 1 5 86 2 75 56 4 5 84 2 82 30 60 49 7 4 83 3 00 50 1 4 78 3...

Page 24: ...9 MATCHING INDOOR COMPONENTS G1UA 1 2 CASED UPFLOW G1HD HORIZONTAL DUCT G2FD MULTI POSITION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNAC...