6
Mounting Installation Plate
Ensure that the wall is strong enough to withstand
the weight of the unit. Otherwise, it is necessary
to reinforce the wall with plates, beams or pillars.
Use the level gauge for horizontal mounting, and
fix it with 5 suitable screws.
In case the rear piping draws out, drill a hole
65mm in diameter with a cone drill, slightly
lower on the outside wall (see figure).
Recommended Mounting Plate
Retention Spots And Dimensions
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the
mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the
front grille) to release the claws.
Mounting plate
Mounting plate
fixing screw
Inside
Outside
Through
the wall
hole
Ø 65mm
Drain
hose
position
Recommended mounting
plate retention spots
(5 spots in all)
Use tape measure as shown.
Position the end of a tape measure
at
Gas pipe end
Liquid pipe end
166
184
181.7
55.5
54.5
153.8
263
51.9
800
45.9
42.2
288
42.2
45.9
Hole with cone drill
All dimensions are in mm
Caulking
Wall embedded
pipe (Field
supply)
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
Ø 65
Mount The Unit Onto The Installation
Plate
Hook the indoor unit onto the upper portion of
the installation plate (Engage the two hooks at
the rear top of the indoor unit with the upper
edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate
by moving it to the left and right.
Mounting
plate
Clip
Mark
(rear side)
Bottom frame
Front grille
Mounting
plate
Interconnecting
wires
Hang indoor unit’s hook here.
Wire guide
When stripping
the ends of
interconnecting
wires in advance,
bind right ends
of wires with
insulating tape.
Water Drainage Piping
The indoor drain pipe must be in a downward
gradient for smooth drainage. Avoid situations
that are likely to cause water to leak.
End
dipped
into
water
Water
leaking
Water
leaking
Water
leaking
Wrong
Wrong
Wrong
Drain
Water Drainage
Water
retention
Correct