AIR CONDITIONER UNIT OPERATION
Dry Mode
•
When the air humidity is high, the unit can
operate in dry mode. Press <MODE> button
and choose <DRY>.
•
If the room temperature is 2°C/3.6°F higher
than the set temperature, the air conditioner
will operate under cooling mode until it
reaches within the 2°C/3.6°F range of
difference compared to the set temperature
before it converts to dry mode.
•
If the room temperature is within the 2°C/
3.6°F range of difference compared to the
set temperature, it will directly operate under
dry mode.
•
The unit will operate at LOW speed under
dry mode.
Air Flow Control
•
For more effective air circulation, you can
manually adjust the air discharge grille to
the left or right.
•
During cool mode operation and dry mode
operation, do not direct the air discharge
louver downwards for too long. If operating
continues in this way, condensation may
occur on the louver, thus resulting in
drippings.
Frost Prevention
•
When the air filter is dirty, the evaporating
temperature will decrease and eventually
cause frosting.
•
If the evaporating temperature reaches
-1°C/33.8°F, the unit will trip.
Fan Speed And Rated Cooling Capacity
•
The rated cooling capacity is provided at the
high fan speed.
•
The cooling capacity is lower when the unit
is operating at MEDIUM and LOW fan
speed.
Notes On Flaps And Louvers Angles
•
When “
SWING button
” is selected, the flaps
swinging range depends on the operation
mode. (See the figure.)
ATTENTION
•
Always use a remote controller to adjust the
flaps angle. If you attempt to move it forcibly
with hand when it is swinging, the
mechanism may be broken.
•
Be careful when adjusting the louvers. Inside
the air outlet, a fan is rotating at a high speed.
In COOL, DRY and FAN mode
When stop
operation
Upper limit 50˚
Lower limit 70˚
OPERATING RANGE
Cooling Unit
Temperature
Ts °C / °F
Th °C / °F
Minimum indoor temperature
19.0 / 66.2
14.0 / 57.2
Maximum indoor temperature
32.0 / 89.6
23.0 / 73.4
Minimum outdoor temperature
19.4 / 66.9
–
Maximum outdoor temperature
46.0 / 114.8
–
Ts: Dry bulb temperature.
Th: Wet bulb temperature.