SAFETY PRECAUTIONS
This manual provides the procedures of installation to ensure a safe and good standard
of operation for the air conditioner unit.
Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and
keep it for future reference.
INSTALLATION MANUAL
!
CAUTION
Please take note of the following important
points when installing.
•
Do not install the unit where leakage of
flammable gas may occur.
If gas leaks and accumulates around the
unit, it may cause fire ignition.
•
Ensure that drainage piping is connected
properly.
If the drainage piping is not connected
properly, it may cause water leakage
which will dampen the furniture.
•
Do not overcharge the unit.
This unit is factory pre-charged.
Overcharge will cause over-current or
damage to the compressor.
•
Ensure that the unit’s panel is closed after
service or installation.
Unsecured panels will cause the unit
to operate noisily.
•
Sharp edges and coil surfaces are potential
locations which may cause injury hazards.
Avoid from being in contact with these
places.
•
Before turning off the power supply, set the
remote controller’s ON/OFF switch to the
“OFF” position to prevent the nuisance
tripping of the unit.
If this is not done, the
unit’s fans will start turning automatically
when power resumes, posing a hazard to
service personnel or the user.
•
Do not operate any heating apparatus too
close to the air conditioner unit.
This may
cause the plastic panel to melt or deform as a
result of the excessive heat.
•
Ensure the color of wires of the outdoor
unit and the terminal markings are same
to the indoors respectively.
•
IMPORTANT : DO NOT INSTALL OR
USE THE AIR CONDITIONER UNIT IN
A LAUNDRY ROOM.
•
Don’t use joined and twisted wires for
incoming power supply.
!
WARNING
• Installation and maintenance should be
performed by qualified persons who are familiar
with local code and regulation, and experienced
with this type of appliance.
• All field wiring must be installed in accordance
with the national wiring regulation.
• Ensure that the rated voltage of the unit
corresponds to that of the name plate before
commencing wiring work according to the
wiring diagram.
• The unit must be GROUNDED to prevent
possible hazard due to insulation failure.
• All electrical wiring must not touch the
refrigerant piping, or any moving parts of the
fan motors.
• Confirm that the unit has been switched OFF
before installing or servicing the unit.
• Disconnect from the main power supply
before servicing the air conditioner unit.
• DO NOT pull out the power cord when the
power is ON. This may cause serious electrical
shocks which may result in fire hazards.
• Keep the indoor and outdoor units, power cable
and transmission wiring, at least 1m from TVs
and radios, to prevent distorted pictures and
static. {Depending on the type and source of
the electrical waves, static may be heard even
when more than 1m away}.