ATTENTION

Your product is marked with this symbol. This means that at the end of its service life it should not be mixed 
with other non-classified household waste. Therefore, disposal should be carried out in compliance with 
the corresponding local and national regulations, in a correct and environment-friendly manner.

The dismantling of the air conditioning unit, as well as the processing of refrigerant, oil and other components, 
should be carried out by a qualified technician and in compliance with the applicable legislation.

Contact your local authorities for further information

Installation Instructions

Inspection

Upon reception, inspect the equipment and 
notify  both  the  carrier  and  the  insurance 
company,  in  writing,  of  any  possible 
damage.

Environmental protection

Eliminate  packing  in  accordance 
with  the  regulations  in  force  on 
environmental conservation.

Installation of indoor unit

Fasten  the  mounting  plate  to  the  wall. 
Tighten screws slightly. Level the mounting 
plate,  and  then  tighten  screws  to  a 
maximum (Fig. 2).
If the tubing goes through the back of the 
unit,  drill  a  50  mm.  diameter  hole  in  the 
wall. The outer side of this hole should be 
slightly below the inner side (Figs. 3 and 7). 
Install the through guide.
The  refrigerant  lines  can  be  installed  in 
different positions (Fig. 6).

Installation of the interconnecting tubing 
and  wiring,  with  the  central  mounting 
plate located at the back of the chassis.

Hang  the  upper  part  of  the  unit  over  the 
mounting panel and press forward. Fasten 
the  indoor  unit  to  the  mounting  plate 
permanently.
Bend the tubing carefully, without flattening 
or obstructing it.
Pass  the  tubing  and  cables  of  the  unit 
through the hole; and hand the upper part 
of the indoor unit on the upper edge of the
mounting plate (see Fig. 2).
Make  sure  the  unit  is  installed  properly,  
moving  it  first  to  the  left  and  then  to  the 
right.

Condensed water drain

The drain pipe of the unit is flexible and can 
be  placed  in  different  positions.  The  drain 
line should include an elbow (Ushaped) (Fig. 
4). Connect a plastic condensed water drain 
pipe with a 12 mm. inner diameter.
The  drain  pipe  should  be  fastened  to  the 
cooling lines with vinyl tape (see Fig. 6).

Typical installation (Fig. 1)

This illustration shows, in general, a typical 
installation of this equipment.
After  carrying  out  a  drain  test,  apply  vinyl 
tape, ref. 5, joining all tubing.

Wiring

1- Open the front panel.
2- Remove the wiring cover.
3-  Locate the connecting cable from 

the indoor unit, passing though the 
connecting hole.

4-  Follow indication of Fig. 8 for wiring 

connections.

5-  Install the electrical connection 

protector.

6- Mount the front panel.

Cable section

Sizes

09

12

18

24

Power 
supply

mm

2

3 x 2,5

Interconnection
(ind./out.)

4 x 2,5

Fuse 
(D Curve)

A

10

16

16

20

Prior to final approval of the

installation

Check:

-  The voltage is always between 

198-254 V.

-  The power supply cable section 

is, at least, that recommended.

-  Condensed  water  drainage 

is  carried  out  correctly,  and 
there are no leaks in the water 
circuit.

-  Operating  instructions  have 

been given to the user.

-  Information has been given on 

the  need  to  clean  the  air  filter 
periodically.

-  Maintenance  instructions  have 

been  given,  or  a  contract  has 
been  made  for  periodical 
servicing.

Wiring

BU: Blue
BK: Black
BN: Brown
YE: Yellow/green

EVKC 09, 12, 18, 24

Fig. 8

Outdoor unit

connection

N(1) 2

3

BU BK

BN

YE

GB

Summary of Contents for EVKC 18 DSAAAR

Page 1: ...FC Le programme LCP recouvre les groupes refroidisseurs de liquides froid seul et r versible condensation par air jusqu 600 kW Johnson Controls Manufacturing Espa a S L participa no Programa de Certif...

Page 2: ...by johnson controls 2...

Page 3: ...by johnson controls 3 Fig 1 Fig 2 Fig 3 15 cm 15 cm 70 cm 15 cm 15 cm 200 cm 5 6 7 30 cm 50 cm 2 3 4 1 5...

Page 4: ...tres Filtros Filtri Filter Filters Filtre Interruptor ON OFF ON OFF switch Interrupteur ON OFF Interruptor ON OFF Interruttore ON OFF EIN AUS Schalter Str mbrytare ON OFF Manguera de desag e Drain hos...

Page 5: ...ata Durchsatz Luchtdebiet Str m Velocidad alta High speed Grande vitesse Velocidade elevada Velocit alta Hohe Geschwindigkeit Hoge snelheid H y hastighet m3 h 500 560 850 900 m3 s 0 14 0 16 0 24 0 25...

Page 6: ...drenaje debe fijarse a las l neas de refrigeraci n con cinta de vinilo ver fig 6 Instalaci n t pica fig 1 Este dibujo nos muestra en forma gene ralizada una instalaci n t pica de estos equipos Despu...

Page 7: ...e tubing carefully without flattening or obstructing it Pass the tubing and cables of the unit through the hole and hand the upper part of the indoor unit on the upper edge of the mounting plate see F...

Page 8: ...Le tube de drainage doit tre fix aux lignes frigorifiques avec un ruban en vinyle Voir fig 6 Installation typique fig 1 Ce dessin nous montre d une fa on g n rale une installation typique de ces appa...

Page 9: ...2 mm O tubo de drenagem dos condensados deve ser fixado s linhas de refrigera o por meio de fita de vinil vejase a Fig 6 Instala o t pica Fig 1 Este desenho mostra de forma genera lizada uma instala o...

Page 10: ...nsa deve essere fis sato alle tubazioni frigorifere con nastro vini lico fig 6 Installazione tipica fig 1 La figura mostra in modo generalizzato un installazione tipica di questi apparecchi Dopo aver...

Page 11: ...e ffnung in der Wand f hren und oberen Teil des Innenger ts auf die Oberkante der Montageplatte h ngen siehe Fig 2 Durch ein versuchsweises Hin und Herschieben des Geh uses die korrekte Anbringung des...

Page 12: ...an De afvoerbuis dient op de koelleidingen met vin yltape aangesloten te worden zie fig 6 Standaard installatie fig 1 In de afbeelding is de gebruikelijke insta llatie van deze toestellen in het algem...

Page 13: ...ens r rledning og ledninger gjennom hullet og heng den innvendige enhetens vre del over monteringsplatens vre kant se figur 2 Sjekk at enheten er riktig montert ved la den gli fra en side til den andr...

Page 14: ......

Page 15: ...S Y ESPECIFICACIONES T CNICAS APLICADAS LUGAR Sabadell Espa a EN12100 1 EN12100 2 EN563 EN294 EN953 EN378 EN60335 1 EN60335 2 40 EN61000 3 EN55014 1 EN55014 2 EN55104 98 37 EEC 2006 95 EEC 2004 108 EE...

Page 16: ...www johnsoncontrols com...

Reviews: