Note: 1. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.

2. The pressure thru the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air duct 

system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation.

FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM

TABLE 10: SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE

Model No.

DEB

Blower

Speed

Setting

External Static Pressure (Inches Water Gauge)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

CFM

W

CFM

W

CFM

W

CFM

W

CFM

W

CFM

W

CFM

W

CFM W CFM W CFM W CFM W

018

(1.5)

High

-

-

-

-

-

-

-

-

689

374

593

361

497

347

-

-

-

-

-

-

-

-

Medium

-

-

-

-

-

-

690

231

659

210

487

188

-

-

-

-

-

-

-

-

-

-

Low

741

226

686

212

632

198

577

185

453

165

-

-

-

-

-

-

-

-

-

-

-

-

024

(2.0)

High

-

-

-

-

-

-

-

-

-

-

-

-

990

468

888

456

786

444

684

432

-

-

Medium

-

-

-

-

961

331

902

321

841

305

781

290

720

274

660

257

-

-

-

-

-

-

Low

810

261

765

250

720

238

675

227

627

212

-

-

-

-

-

-

-

-

-

-

-

-

030

(2.5)

High

-

-

-

-

-

-

-

-

1171

504

1080

486

990

468

888

456

786

444

-

-

-

-

Medium

1080

351

1021

341

961

331

902

321

841

305

781

290

-

-

-

-

-

-

-

-

-

-

Low

810

261

765

240

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

036

(3.0)

High

-

-

-

-

1440

605

1361

581

1273

555

1185

530

1097

504

1004 480

912

456

-

-

-

-

Medium

1465

531

1395

512

1325

492

1255

473

1167

446

1079

419

992

392

-

-

-

-

-

-

-

-

Low

1316

473

1260

455

1204

438

1148

420

1069

396

990

372

911

348

-

-

-

-

-

-

-

-

042

(3.5)

High

-

-

-

-

1728

725

1633

697

1527

666

1422

635

1317

605

1205 576 1094 547

-

-

-

-

Medium

-

-

1674

614

1590

590

1506

567

1400

535

1295

502

1190

470

1063 428

-

-

-

-

-

-

Low

1579

567

1512

546

1444

525

1377

504

1282

476

1188

447

1093

418

-

-

-

-

-

-

-

-

048

(4.0)

High

-

-

1985

870

1939

850

1897

830

1813

800

1728

770

1644

740

1559 707 1474 673 1389 640

-

-

Medium

1694

690

1662

673

1629

657

1597

640

1542

623

1486

607

1431

590

1336 563 1240 537

-

-

-

-

Low

1385

520

1349

510

1312

500

1276

490

1235

480

-

-

-

-

-

-

-

-

-

-

-

-

060

(5.0)

High

-

-

-

-

2450 1213 2366 1165 2282 1117 2198 1068 2114 1020 1989 993 1864 967 1739 940

-

-

Medium

2339 1170 2275 1118 2211 1067 2147 1015 2083

963

2019

912

1955

860

1854 824 1753 788 1652 752

-

-

Low

1929

940

1877

903

1824

867

1772

830

1720

793

1667

757

1615

720

1586 706 1557 691 1528 677

-

-

TABLE 11: ADDITIONAL STATIC RESISTANCE

Description

Resistance, IWG

CFM

500

600

700

800

900

1,000

1,100

1,200

1,300

1,400

1,500

1,600

Wet Evaporator Coil

.01

.01

.01

.02

.03

.04

.05

.06

.07

.08

.09

.09

Economizer

.00

.00

.00

.01

.01

.01

.01

.02

.03

.04

.05

.06

Filter/Frame Kit

.01

.02

.02

.02

.02

.02

.03

.03

.03

.03

.04

.05

Electric Heat

.02

.03

.03

.03

.04

.04

.05

.06

.07

.08

.09

.10

REFER TO ELECTRICAL

DATA TABLES TO SIZE

THE DISCONNECT

POWER WIRING

24 VOLT

TRANSFORMER

UNIT TERMINAL STRIP

THERMOSTAT

NOTE:
HEAT ANTICIPATOR
SHOULD BE SET AT 0.25
AMPS FOR ALL MODELS.

PROGRAMMABLE

THERMOSTAT ONLY

** = Minimum wire size of 18 AWG

wire should be used for all field

installed 24 volt wire.

**

* = Only required on units with

supplemental electric heat.

*

CONTROL WIRING

CAUTION: Label all wires prior to discon-

nection when servicing con-
trols. Wiring errors can cause
improper and dangerous op-
eration. Verify proper operation
after servicing.

Summary of Contents for AFFINITY 360101-XTG-A-0108

Page 1: ...needs to carry less inventory LOWER INSTALLATION COST Installation time and costs are reduced by easy power and control wiring connections The small base dimension means less space is required on the...

Page 2: ...2 TON DEB018 6 4 COOLING CAPACITIES 2 TON DEB024 7 5 COOLING CAPACITIES 2 1 2 TON DEB030 8 6 COOLING CAPACITIES 3 TON DEB036 9 7 COOLING CAPACITIES 3 1 2 TON DEB042 10 8 COOLING CAPACITIES 4 TON DEB0...

Page 3: ...condenser fan does not disrupt neighboring areas and does not dry out vegetation surrounding the unit The warm air from the top mounted fan is blown up away from the structure and any landscaping Thi...

Page 4: ...ed side return and unit mounted down shot return applications Damper capable of providing 0 thru 50 of outdoor air field supplied Closes on power loss includes hood and screen assembly RECTANGLE TO RO...

Page 5: ...0 2 400 2 400 2 400 2 800 2 800 CONDENSER COIL ROWS DEEP 1 1 1 1 1 1 1 FINS PER INCH 18 16 20 18 16 13 20 FACE AREA Sq Ft 8 3 8 3 8 3 8 3 11 7 16 4 16 4 CHARGE REFRIGERANT 22 lbs oz 3 4 3 5 3 13 3 10...

Page 6: ...6 17 2 16 5 14 4 14 9 Total Power Input kW 1 99 2 00 1 96 1 94 2 05 2 06 2 02 2 00 2 11 2 12 2 08 2 06 2 14 2 15 2 10 2 09 2 16 2 17 2 13 2 11 Sensible Capacity MBH 1 Entering Dry Bulb F 86 8 7 12 0 1...

Page 7: ...9 7 19 7 Total Power Input kW 2 61 2 58 2 55 2 51 2 67 2 64 2 60 2 56 2 72 2 69 2 65 2 62 2 87 2 84 2 79 2 76 3 01 2 98 2 93 2 90 Sensible Capacity MBH 1 Entering Dry Bulb F 86 13 4 16 7 17 9 17 9 14...

Page 8: ...Power Input kW 3 38 3 28 3 22 3 22 3 45 3 35 3 29 3 28 3 52 3 42 3 36 3 35 3 66 3 55 3 49 3 48 3 79 3 68 3 62 3 61 Sensible Capacity MBH 1 Entering Dry Bulb F 86 16 5 21 3 22 2 22 3 18 5 23 4 23 1 23...

Page 9: ...ut kW 4 05 3 92 3 93 3 85 4 07 3 94 3 95 3 87 4 09 3 96 3 97 3 89 4 15 4 02 4 02 3 95 4 21 4 08 4 08 4 00 Sensible Capacity MBH 1 Entering Dry Bulb F 86 17 5 23 3 25 0 24 4 19 9 26 3 26 6 26 0 22 3 29...

Page 10: ...20 4 22 4 47 4 35 4 27 4 29 4 54 4 42 4 34 4 35 4 69 4 57 4 48 4 50 4 84 4 71 4 63 4 64 Sensible Capacity MBH 1 Entering Dry Bulb F 86 22 4 29 3 30 8 31 2 24 8 32 1 32 0 32 4 27 3 34 9 33 1 33 6 29 3...

Page 11: ...21 5 21 5 49 5 43 5 34 5 33 5 62 5 55 5 46 5 45 5 72 5 66 5 56 5 55 5 83 5 76 5 66 5 65 Sensible Capacity MBH 1 Entering Dry Bulb F 86 27 0 33 2 37 8 37 4 29 6 36 1 38 3 37 9 32 3 39 1 38 8 38 3 34 3...

Page 12: ...58 7 07 6 90 6 79 6 75 7 25 7 06 6 96 6 91 7 47 7 28 7 17 7 12 7 69 7 50 7 38 7 33 Sensible Capacity MBH 1 Entering Dry Bulb F 86 33 5 42 4 45 0 45 3 37 5 47 1 46 9 47 2 41 4 51 8 48 8 49 1 44 9 53 7...

Page 13: ...1205 576 1094 547 Medium 1674 614 1590 590 1506 567 1400 535 1295 502 1190 470 1063 428 Low 1579 567 1512 546 1444 525 1377 504 1282 476 1188 447 1093 418 048 4 0 High 1985 870 1939 850 1897 830 1813...

Page 14: ...Model No Stage KW Total AMPS 018 208 230 1 60 9 0 48 0 1 1 2 6 2NH04500506 1 3 8 5 0 18 1 20 8 25 8 29 3 30 30 30 30 2NH04500706 2 5 6 7 5 27 1 31 3 37 1 42 3 40 45 40 45 024 208 230 1 60 11 2 60 0 1...

Page 15: ...hange without notice Certified dimensions will be provided upon request UNIT CONDENSATE CONNECTION NPTI TRAP REQUIRED OVERALL SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING COMPRESSOR SERVICE ACCESS...

Page 16: ...Shipping Weight Operating Weight Corner Weights Economizer lbs Roof Curb lbs A B C D 018 318 313 86 76 73 83 40 8 70 14 75 024 324 319 88 77 75 85 030 333 328 85 81 82 86 036 338 333 91 80 78 88 042...

Page 17: ...OWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOSTAT SLAB ON GROUND INSTALLATION ROOF CURB INSTALLATION BOTTOM DUCT...

Page 18: ...ED PANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPLY AIR DUCT RECOMMENDED DUCT SIZE SUPPLY AIR DUCT x RETURN AIR DUCT x UNIT BASE RAIL UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FR...

Page 19: ...trols Unitary Products 19 FIGURE 9 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY DEB MODELS 15695BASH0301 SEE DETAIL A T2 M1 2 DETAIL A BLK BLK CCH L1 T1 OPTIONAL CCH S P CONFIGURATION BLK BLK CCH...

Page 20: ...tandard 24 O C beams without modification to building structure duct work and base unit 10 Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPTI c...

Page 21: ...section shall have a primary limit control s and automatic reset to prevent the heating element system from operating at an excessive temperature 3 The heating section assembly shall slide out of the...

Page 22: ...360101 XTG A 0108 22 Johnson Controls Unitary Products...

Page 23: ...360101 XTG A 0108 Johnson Controls Unitary Products 23...

Page 24: ...hout notice Printed in U S A 360101 XTG A 0108 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 263146 XTG A 0206 036 21753 001 A 0206 Johnson Controls Unitary Products 5005 York...

Reviews: