Johnson Controls Unitary Products

3

STANDARD FEATURES/BENEFITS (CONT.)

UTILITY CONNECTIONS MADE EASY -

 Electrical utility 

knockouts are provided through the bottom as well as the side 
of the unit. Utility connections can be made quickly and with a 
minimum amount of field labor. A field supplied and  field 
installed electrical disconnect switch must be installed.

CONVERTIBLE AIRFLOW DESIGN -

 The bottom duct 

openings are covered when they leave the factory ready to be 
used for a side supply / side return application. If a bottom supply 
/ bottom return application is desired, you simply remove the two 
panels from the bottom of the unit and place them in the side 
supply / side return duct openings. No panel cutting is required 
and no accessory panel is necessary. Convertible airflow design 
allows maximum field flexibility and minimum inventory.

CONDENSATE PAN -

 A non-corrosive, long-lasting, water-tight 

pan is positioned below the evaporator coil to collect and drain 
all condensate. Less collection of stagnate condensate will 
build-up. The condensate pan conforms to ASHRAE 62-89 
standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN -

 The heavy duty, 3/4 inch NPTI copper 

connection is more tolerable during installation and is more 
durable over time. The connection is rigidly mounted to assure 
proper fit and leak tight seal.

DURABLE FINISH -

 With a heavy duty cabinet made of powder-

painted, galvanized steel the neutral color blends into 
surrounding areas. The powered paint, provides a better paint to 
steel bond, which resists corrosion and rust creep. The special 
primer formulas and glossy earth tone finish insure less fading 
when exposed to sunlight and offers a more attractive on site 
appearance. This paint finish exceeds ASTM-B117 standards for 
750 hours salt spray rating, the highest in the industry.

FULL PERIMETER BASE RAILS -

 The easily removable base 

rails provide a solid foundation for the entire unit and protects 
the unit during shipment. The rails provide fork lift access from 
all sides, and rigging holes are also provided so that an 
overhead crane can be used to place the units on a roof. On 
applications when the unit is placed on a pad, the base will 
keep the unit off the pad to deter corrosion. On applications 
where height is limited, the 2-3/8 inch high base rails may be 
removed on location.

MORE ATTRACTIVE APPEARANCE -

 A single piece “Water 

Shed” top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation and 
provides a wider variety of installations. The one piece design 
adds greater water integrity. Rounded corners with water drip 
edges add to the attractive appearance. The cabinet panels 
have a non-fibrous insulation that does not add insulation fibers 
into conditioned area.

TOP DISCHARGE -

 The top discharge condenser fan does not 

disrupt neighboring areas and does not dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan is 
blown up away from the structure and any landscaping. This 
allows compact location on multi-unit applications.

CONDENSER COIL GRILLE -

 A multi-piece totally enclosed, 

rigidly mounted condenser coil grille provides protection from 
objects and personal after installation and provides protection 
during transit and installation.

LOW OPERATING SOUND LEVEL -

 The upward air flow carries 

the normal operating noise up and away from the living area. The 
rigid top panel effectively isolates any motor sound. Isolator 
mounted compressor and the rippled fins of the condenser coil 
muffle the normal fan motor and compressor operating sounds. 
The unique formed base pan also aids in sound alterations with it's 
“Super-Structure” design. This design strategically places 
embossments in the pan for optimum strength and rigidity.

FAN SYSTEM -

 All models operate over a wide range of design 

conditions with a 3-speed direct-drive fan motor. These units 
easily match all types of applications and provides greater on 
site flexibility to match comfort requirement.

SIMPLE CONTROL CIRCUIT -

 A low voltage printed circuit 

board contains a low voltage terminal strip. The electrical 
control box is not located in the compressor compartment. All 
wiring internal to the unit is color/number coded.

PROTECTED COMPRESSOR -

 The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high pressure 
relief valve and a temperature sensor which protect the 
compressor if undesirable operating conditions occur.

EXCLUSIVE COIL DESIGN -

 Grooved copper tubes and 

enhanced aluminum fin construction improves heat transfer for 
maximum efficiency and durability.

LOW MAINTENANCE -

 Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no annual 
maintenance adding greater reliability to the unit. Blower 
assembly can be easily removed for cleaning by the unique 
“Slip- Track” slide-out blower assembly.

SECURED SERVICE ACCESS PORTS -

 Protected, externally 

mounted, re-usable service access ports are provided on both 
the high and low lines for ease of evacuating and charging the 
system. No final field mounting required.

EASY SERVICE ACCESS -

 A large, single panel covers the 

electrical controls and makes servicing easy. The blower 
compartment has an additional large panel with a built-in 
handle tab. Removing this panel will allow the blower assembly 
to slide-out for easy removal for maintenance and ease of 
trouble shooting.

REPLACEMENT PARTS -

 The installer has no need to carry 

an inventory of unique parts or needs special training to replace 
any of the components parts for these units. All are easily 
obtained from Source 1 or other part houses.

FIELD-INSTALLED ACCESSORIES

ECONOMIZER DOWN DISCHARGE / SUPPLY KIT -

 

Modulating integrated economizer provides simultaneous 
operation between the mechanical cooling and economizer 

Summary of Contents for AFFINITY 360101-XTG-A-0108

Page 1: ...needs to carry less inventory LOWER INSTALLATION COST Installation time and costs are reduced by easy power and control wiring connections The small base dimension means less space is required on the...

Page 2: ...2 TON DEB018 6 4 COOLING CAPACITIES 2 TON DEB024 7 5 COOLING CAPACITIES 2 1 2 TON DEB030 8 6 COOLING CAPACITIES 3 TON DEB036 9 7 COOLING CAPACITIES 3 1 2 TON DEB042 10 8 COOLING CAPACITIES 4 TON DEB0...

Page 3: ...condenser fan does not disrupt neighboring areas and does not dry out vegetation surrounding the unit The warm air from the top mounted fan is blown up away from the structure and any landscaping Thi...

Page 4: ...ed side return and unit mounted down shot return applications Damper capable of providing 0 thru 50 of outdoor air field supplied Closes on power loss includes hood and screen assembly RECTANGLE TO RO...

Page 5: ...0 2 400 2 400 2 400 2 800 2 800 CONDENSER COIL ROWS DEEP 1 1 1 1 1 1 1 FINS PER INCH 18 16 20 18 16 13 20 FACE AREA Sq Ft 8 3 8 3 8 3 8 3 11 7 16 4 16 4 CHARGE REFRIGERANT 22 lbs oz 3 4 3 5 3 13 3 10...

Page 6: ...6 17 2 16 5 14 4 14 9 Total Power Input kW 1 99 2 00 1 96 1 94 2 05 2 06 2 02 2 00 2 11 2 12 2 08 2 06 2 14 2 15 2 10 2 09 2 16 2 17 2 13 2 11 Sensible Capacity MBH 1 Entering Dry Bulb F 86 8 7 12 0 1...

Page 7: ...9 7 19 7 Total Power Input kW 2 61 2 58 2 55 2 51 2 67 2 64 2 60 2 56 2 72 2 69 2 65 2 62 2 87 2 84 2 79 2 76 3 01 2 98 2 93 2 90 Sensible Capacity MBH 1 Entering Dry Bulb F 86 13 4 16 7 17 9 17 9 14...

Page 8: ...Power Input kW 3 38 3 28 3 22 3 22 3 45 3 35 3 29 3 28 3 52 3 42 3 36 3 35 3 66 3 55 3 49 3 48 3 79 3 68 3 62 3 61 Sensible Capacity MBH 1 Entering Dry Bulb F 86 16 5 21 3 22 2 22 3 18 5 23 4 23 1 23...

Page 9: ...ut kW 4 05 3 92 3 93 3 85 4 07 3 94 3 95 3 87 4 09 3 96 3 97 3 89 4 15 4 02 4 02 3 95 4 21 4 08 4 08 4 00 Sensible Capacity MBH 1 Entering Dry Bulb F 86 17 5 23 3 25 0 24 4 19 9 26 3 26 6 26 0 22 3 29...

Page 10: ...20 4 22 4 47 4 35 4 27 4 29 4 54 4 42 4 34 4 35 4 69 4 57 4 48 4 50 4 84 4 71 4 63 4 64 Sensible Capacity MBH 1 Entering Dry Bulb F 86 22 4 29 3 30 8 31 2 24 8 32 1 32 0 32 4 27 3 34 9 33 1 33 6 29 3...

Page 11: ...21 5 21 5 49 5 43 5 34 5 33 5 62 5 55 5 46 5 45 5 72 5 66 5 56 5 55 5 83 5 76 5 66 5 65 Sensible Capacity MBH 1 Entering Dry Bulb F 86 27 0 33 2 37 8 37 4 29 6 36 1 38 3 37 9 32 3 39 1 38 8 38 3 34 3...

Page 12: ...58 7 07 6 90 6 79 6 75 7 25 7 06 6 96 6 91 7 47 7 28 7 17 7 12 7 69 7 50 7 38 7 33 Sensible Capacity MBH 1 Entering Dry Bulb F 86 33 5 42 4 45 0 45 3 37 5 47 1 46 9 47 2 41 4 51 8 48 8 49 1 44 9 53 7...

Page 13: ...1205 576 1094 547 Medium 1674 614 1590 590 1506 567 1400 535 1295 502 1190 470 1063 428 Low 1579 567 1512 546 1444 525 1377 504 1282 476 1188 447 1093 418 048 4 0 High 1985 870 1939 850 1897 830 1813...

Page 14: ...Model No Stage KW Total AMPS 018 208 230 1 60 9 0 48 0 1 1 2 6 2NH04500506 1 3 8 5 0 18 1 20 8 25 8 29 3 30 30 30 30 2NH04500706 2 5 6 7 5 27 1 31 3 37 1 42 3 40 45 40 45 024 208 230 1 60 11 2 60 0 1...

Page 15: ...hange without notice Certified dimensions will be provided upon request UNIT CONDENSATE CONNECTION NPTI TRAP REQUIRED OVERALL SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING COMPRESSOR SERVICE ACCESS...

Page 16: ...Shipping Weight Operating Weight Corner Weights Economizer lbs Roof Curb lbs A B C D 018 318 313 86 76 73 83 40 8 70 14 75 024 324 319 88 77 75 85 030 333 328 85 81 82 86 036 338 333 91 80 78 88 042...

Page 17: ...OWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOSTAT SLAB ON GROUND INSTALLATION ROOF CURB INSTALLATION BOTTOM DUCT...

Page 18: ...ED PANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPLY AIR DUCT RECOMMENDED DUCT SIZE SUPPLY AIR DUCT x RETURN AIR DUCT x UNIT BASE RAIL UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FR...

Page 19: ...trols Unitary Products 19 FIGURE 9 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY DEB MODELS 15695BASH0301 SEE DETAIL A T2 M1 2 DETAIL A BLK BLK CCH L1 T1 OPTIONAL CCH S P CONFIGURATION BLK BLK CCH...

Page 20: ...tandard 24 O C beams without modification to building structure duct work and base unit 10 Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPTI c...

Page 21: ...section shall have a primary limit control s and automatic reset to prevent the heating element system from operating at an excessive temperature 3 The heating section assembly shall slide out of the...

Page 22: ...360101 XTG A 0108 22 Johnson Controls Unitary Products...

Page 23: ...360101 XTG A 0108 Johnson Controls Unitary Products 23...

Page 24: ...hout notice Printed in U S A 360101 XTG A 0108 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 263146 XTG A 0206 036 21753 001 A 0206 Johnson Controls Unitary Products 5005 York...

Reviews: