Electrical data
ZQ04 to 06 Standard Static Indoor Blower - Without Powered Convenience Outlet
Table 7: ZQ04-06 Standard Static Indoor Blower - Without Powered Convenience Outlet
Compressor 1
Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating
/ Pwr Exh
Si
ze
(T
on
s)
N
om
in
al
U
ni
t V
ol
ta
ge
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA
(Amps)
2, 3
Min Fuse
/ Breaker
Size (Amps)
Max Fuse
/ Breaker
Size (Amps)
FLA LRA
MCA
w/Pwr Exh (Amps)
Min Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
Max Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
FLA LRA
None
-
-
-
27.3
30
40
27
89 28.8 30
40
29
93
10625 4.9
1
23.6
37.8
40
40
35
89 39.6 40
40
36
93
208-1-60 15.4 83.9 24
1.4
6.6
1.5
11125 7.9
1
38
55.8
60
60
51
89 57.6 60
60
53
93
None
-
-
-
26.7
30
40
26
89
28
30
40
28
92
10625 6.5
1
27.1
41.4
45
45
38
89
43
45
45
40
92
230-1-60 15.4 83.9 24
1.4
6
1.3
11125 10.5
1
43.8
62.3
70
70
57
89 63.9 70
70
59
92
None
-
-
-
21
25
30
21
78 22.1 25
30
22
81
10625 4.9
1
13.6
25.3
30
30
23
78 26.6 30
30
24
81
11125 7.9
1
21.9
35.6
40
40
33
78
37
40
40
34
81
208-3-60 10.4 73
16
1.4
6.6
1.1
11625 12
1
33.3
49.9
50
50
46
78 51.3 60
60
47
81
None
-
-
-
20.4
25
30
20
78 21.4 25
30
22
81
10625 6.5
1
15.6
27
30
30
25
78 28.3 30
30
26
81
11125 10.5
1
25.3
39.1
40
40
36
78 40.4 45
45
37
81
230-3-60 10.4 73
16
1.4
6
1
11625 16
1
38.5
55.6
60
60
51
78 56.9 60
60
52
81
None
-
-
-
11.3
15
15
11
42 11.8 15
15
12
43
10646
6
1
7.2
13
15
15
12
42 13.6 15
15
13
43
11146 11.5
1
13.8
21.3
25
25
20
42 21.9 25
25
20
43
460-3-60 5.8 38
9
0.8
3.2
0.5
11446 14
1
16.8
25
25
25
23
42 25.6 30
30
24
43
None
-
-
-
7.8
15
15
8
39 8.2 15
15
8
40
11058 9.2
1
8.9
14.1
15
15
13
39 14.6 15
15
13
40
04 (3)
575-3-60 3.8 36.5
6
0.6
6
0.4
11458 13.8
1
13.3
19.6
20
20
18
39 20.1 25
25
19
40
None
-
-
-
34.3
35
50
34 135 35.8 40
50
36 139
10625 4.9
1
23.6
40
40
50
37 135 41.9 45
50
39 139
208-1-60 19.6 130 31
1.4
8.4
1.5
11125 7.9
1
38
58
60
60
53 135 59.9 60
60
55 139
None
-
-
-
33.5
35
50
33 135 34.8 35
50
34 138
10625 6.5
1
27.1
43.4
45
50
40 135 45
45
50
41 138
230-1-60 19.6 130 31
1.4
7.6
1.3
11125 10.5
1
43.8
64.3
70
70
59 135 65.9 70
70
61 138
None
-
-
-
26.9
30
40
27
88
28
30
40
28
91
10625 4.9
1
13.6
27.5
30
40
27
88 28.9 30
40
28
91
11125 7.9
1
21.9
37.9
40
40
35
88 39.3 40
40
36
91
208-3-60 13.7 83.1 21
1.4
8.4
1.1
11625 12
1
33.3
52.1
60
60
48
88 53.5 60
60
49
91
None
-
-
-
26.1
30
35
26
88 27.1 30
40
27
91
10625 6.5
1
15.6
29
30
35
27
88 30.3 35
40
28
91
11125 10.5
1
25.3
41.1
45
45
38
88 42.4 45
45
39
91
230-3-60 13.7 83.1 21
1.4
7.6
1
11625 16
1
38.5
57.6
60
60
53
88 58.9 60
60
54
91
None
-
-
-
12.6
15
15
13
45 13.1 15
15
13
46
10646
6
1
7.2
14
15
15
13
45 14.6 15
15
13
46
11146 11.5
1
13.8
22.3
25
25
20
45 22.9 25
25
21
46
460-3-60 6.2 41
10
0.8
4
0.5
11446 14
1
16.8
26
30
30
24
45 26.6 30
30
24
46
None
-
-
-
9.6
15
15
10
35
10
15
15
10
36
11058 9.2
1
8.9
14.9
15
15
14
35 15.4 20
20
14
36
05 (4)
575-3-60 4.8 33
8
0.6
7.6
0.4
11458 13.8
1
13.3
20.4
25
25
19
35 20.9 25
25
19
36
INSTALLATION MANUAL ZQ SERIES 3 - 5 ton 60 Hertz R-410A
22
Johnson Controls Ducted Systems
Summary of Contents for ZQ Series
Page 2: ...2 INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Page 88: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 88 Johnson Controls Ducted Systems ...
Page 89: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 89 Johnson Controls Ducted Systems ...
Page 90: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 90 Johnson Controls Ducted Systems ...
Page 91: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 91 Johnson Controls Ducted Systems ...