7-17
IM WT3001E-51EN
Harmonic Measurement in Normal Measurement Mode (Option)
1
2
3
4
5
6
7
8
9
10
11
12
13
Index
• Changing the Measurement Function
3.
Press the
U
/
I
/
P
,
S
/
Q
/
λ
/
φ
,
WP
/
q
/
Time
, or
FU
/
FI
/
η
function select key to select the
displayed measurement function.
• When the display mode is set to Single List or Dual List, only the measurement
functions that contain harmonic order data can be selected. Press U/I/P to select U, I,
or P. Press S/Q/λ/φ to select S, Q, λ, φ, φU, or φI.
• Changing the Element/Wiring Unit
4.
Press
ELEMENT
to select the element/wiring unit.
• Changing the Element/Wiring Unit Collectively
5.
Press
SHIFT+ELEMENT (ALL)
. ALL LED illuminates, and the element/wiring
unit of all the displayed items on the displayed page can be changed collectively.
This completes the procedure for changing the displayed items using the function
select keys.
• Using the USER Key
By assigning measurement functions to the USER key, up to four measurement
functions can be directly displayed.
• Assigning Measurement Functions to the USER Key
6.
Press
SHIFT+USER (USER SET)
to display the User Reserved menu.
7.
Press any of the soft keys from
Function 1 to 4
to select the desired Function.
The measurement function selection box appears.
8.
Press the
cursor keys
to select any of the measurement functions starting with
None.
9.
Press
SET
. The symbol for the selected measurement function is displayed at the
highlighted position.
• Changing the Measurement Function with the USER Key
10.
Press
USER
to select the measurement function in the same fashion as step 3.
7.4 Changing the Displayed Items of Numeric Data