<1. OVERVIEW>
1-4
IM 12E04B40-02EN
1st Edition : Mar. 08, 2023-00
*10: For TB830D equipped with pH sensor. You need one converter just for the pH sensor. Selectable only when “-AJ” (no
standard) is specified.
Prepare the following products separately. Refer to GS 12B07B02-E, GS 12J05C02-00E, GS 12A01F01-01EN, GS
19C01B05-01EN.
pH sensor:
PH8EFP-03-TN-TT1-N-G*A (/PHN7 or /PHU7 and without /TT3)
PH8EFP-03-TN-TT3-N-G*A (/PHN7 or PHU7 and with /TT3)
pH holder:
PH8HF-PP-JPT-T-NN-NN*A (/PHN7 without ultrasonic cleaning )
PH8HF-PP-JPT-T-S3-C1*A (/PHU7 with ultrasonic cleaning)
pH converter: FLXA402-A-B-AJ-P1-NN-A□-□□-N-□-J-NN (/PHN7 or /PHU7 )
Pulse generator for clean unit: PG400-A-B-AJ-PU-00-J-ST (/PHU7 with ultrasonic cleaning)
*11: For TB830D equipped with pH sensor. One converter can be shared with the scattered light turbidity detector.
Analog pH sensors can be used.
For the 2nd Input of the converter, specify “-P1” (pH) to connect an analog pH sensor
Prepare the following products separately. Refer to GS 12B07B02-00E, GS 12J05C02-00E, GS 19C01B05-01EN.
pH sensor:
PH8EFP-03-TN-TT1-N-G*A (/PHN2 or /PHU2 and without /TT3)
PH8EFP-03-TN-TT3-N-G*A (/PHN2 or /PHU2 and with /TT3 )
pH holder:
PH8HF-PP-JPT-T-NN-NN*A (/PHN2 without ultrasonic cleaning)
PH8HF-PP-JPT-T-S3-C1*A (/PHU2 with ultrasonic cleaning)
Pulse generator for clean unit: PG400-A-B-□-PU-00-□-ST
*12: For low turbidity (200 NTU or less) measurement range and the application which may generate bubbles, select this code
for head tank.
Do not select this code for high turbidity (above 200 NTU) measurement range because the influence of air bubbles is
small, and the turbidity in the sample may block the air bubble removal piping or reduce the flow rate.
*13: When the Sampling system “-A1” is specified, the sampling system does not support CE or Chinese standards. The
product cannot be sold to the area to which these regulations apply.
*14: When the Sampling system “-A2” or “-A3” is specified, the sampling system does not support CE, RCM, CSA, Chinese
standards. The product cannot be sold to the area to which these regulations apply.
*15: This is selectable only when Sampling system “-NN” or “-A1” or “-A5” is specified.
l
Accessories
Name
Q´ty
Remarks
Silicone cloth
1
Part number: K9210KS
Check tool
1
―
Desiccant
1
For spare. 4 pcs/Q'ty (Part number: K9657RJ)
Desiccant
1
For operation. 4 pcs/Q'ty (Part number: K9657RJ)
(When the code for “Without sampling” is specified)
Pipe mounting hardware
(Option)
1
For “/P” (Option)
Rack mounting hardware
(Option)
1
For “/R” (Option)
Soft vinyl chloride tube
(Ø33 × Ø25 Black)
1 set (1 m x 2) For piping detector
(when the code for “Without sampling” is specified)
Clamp
1
For piping detector
(when the code for “Without sampling” is specified
l
Spare Parts
Name
Part No.
Description
Frequency of
Replacement
LED ASSY (white)
K8004BD
When “-F8” is selected.
3 years
LED ASSY (IR)
K8004BE
When “-FS” is selected.
3 years
Desiccant (4 pcs/Q'ty)*
K9657RJ
―
Yearly
Drain tube
K9411JM
―
Yearly
Fuse
A1633EF
―
―
Fuse
A1624EF
for Sampling system “-A2” “-A3”. The relay
box uses two fuses.
―
1 µm filter
K9008ZD
―
Yearly
*: Use within a year after purchasing.