IM 01R01B30-00E-E 6th edition October 01, 2014 -00
<7. TECHNICAL DATA>
7-5
All Rights Reserved. Copyright © 2003, Rota Yokogawa
OPTIONS
Options
Option
code
Description
Restriction
Indicator
/A12
/A29
/A30
US- engineering units
M12- connector acc. IEC 61076-2-101
M12- connector with plug connector acc. IEC 61076-2-101
Only for indicator E
Only for indicator E or T with limit switches
Only for indicator E or T with limit switches
Marking
/B1
/B4
/B8
/B10
/BG
/BD
Tag plate (SS) fixed by wire and customer specified tag number on
scale
Neutral version
Customer provided marking on label
Percent scale
With customer specified tag number on scale
Dual Scale
Plate 12 x 40 mm; max. 45 digits
Not with Ex-proof type
Max. 45 digits
Adjustment only possible for 1 fluid
Limit switches
/K1
/K2
/K3
/K6
/K7
/K8
/K9
/K10
MIN- contact
MAX- contact
MIN-MAX- contact, MIN-MIN- contact, MAX-MAX- contact
MIN- contact “Fail safe” version
MAX- contact “Fail safe” version
MIN-MAX- contact “Fail safe” version
MIN-MIN- contact “Fail safe” version
MAX-MAX- contact “Fail safe” version
Only for indicator T
Only for indicator T
Only for indicator T
Only for indicator T
Pulse output
/CP
Pulse output, acc. EN 60947-5-6 (NAMUR)
Only for indicator E; not with limit switches
Hazardous area
approvals
/KS1
/KS2
/KS3
/KN1
/ES1
/ES3
/FS1
/CS1
/NS1
/GS1
ATEX intrinsically safe „ia“
ATEX gas and dust proof limit switches, category 2G 1D
ATEX intrinsically safe „ic“
ATEX category 3G „nL“ / 3D
IECEx intrinsically safe „ia“
IECEx intrinsically safe „ic“
FM intrinsically safe / non incendive limit switches (USA)
CSA intrinsically safe / non incendive limit switches (Canada)
NEPSI approval (China)
EAC intrinsically safe „ia“
Not for indicator T without limit switches
Only for indicator T with limit switches
Not for indicator T without limit switches
Not for indicator T without limit switches
Not for indicator T without limit switches
For indicator T only with limit switches
For indicator T only with limit switches; limit switches
only /K1, /K2, /K3, only in combination with power
supply /WxA or /WxB
Not for indicator T without limit switches
Not for indicator T without limit switches; only with /VE
Test and certificates
/H1
/PP
/P2
/P3
/P6
/PM1
/PM4
/PM5
Oil + fat free for wetted surfaces
Pressure test report measuring system
Certificate of Compliance with the order acc. to EN 10204: 2004- 2.1
As /P2 +Test report acc. to EN 10204: 2004- 2.2
Material certificate acc. to EN 10204: 2004- 3.1
PAMI test (1 test point : metering tube)
PAMI test (4 test points : metering tube, connection heads, sealing plug)
PAMI test (5 test points : metering tube, connection pieces, slip on flanges)
Not for /R1 and /R3
Only for tube, connection heads, screw sealing plug
Only for models without valve
Only for models with valve
Only for models with process connection D4, A1, A2
Gost approval
/QR1
/QR2
/QR3
Primary Calibration and Test Confirmation valid in Russia
Primary Calibration and Test Confirmation valid in Kazakhstan
Primary Calibration and Test Confirmation valid in Uzbekistan
See page 4 only with /VE
See page 4 only with /VE
See page 4
Controller
/R1
/R3
Pre pressure controller 1.4571 (only with valve in inlet; for gas
with
variable pre pressure and liquids with variable pre and back pressure)
Back pressure controller 1.4571 (only with valve in outlet; for gas
with variable back pressure)
Only for process connection R3, T3, C3, W3, P1;
only with valve
Only for process connection R3, T3, C3, W3, P1;
only with valve
Delivery to Korea
/KC
With KC-mark for Korea
Eurasian Conformity
/VE
With EAC- mark
Power supply for
electronic transmitter
/UT
RN221N-B1, 20 ... 250V DC/AC, Ex i
Only for indicator E
Power supply
for limit switches
(transmitter relay)
/W1A
/W1B
/W2A
/W2B
/W2E
/W2F
/W4A
/W4B
/W4E
/W4F
KFA5-SR2-Ex1.W / 115 V AC, 1 channel
KFA5-SR2-Ex2.W / 115 V AC, 2 channel
KFA6-SR2-Ex1.W / 230 V AC, 1 channel
KFA6-SR2-Ex2.W / 230 V AC, 2 channel
KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
2x KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
KFD2-SR2-Ex1.W / 24 V DC, 1 channel
KFD2-SR2-Ex2.W / 24 V DC, 2 channel
KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe
2x KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K6, /K7
Only for limit switches /K8, /K9, /K10
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K6, /K7
Only for limit switches /K8, /K9, /K10
Instruction manuals /IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 9 selectable *)
n = 1 to 9 selectable *)
n = 1 to 9 selectable *)
Special order
/Z
Special design must be specification on extra sheet
*) if no instruction manual is selected, only a DVD with instruction manuals is shipped with the flowmeter