<3. INSTALLATION>
3-6
IM 01R01B30-00E-E 6th edition October 01, 2014 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
3.2.3 Conductor M12 connection (Option /A29 or /A30)
Angular mating connector is only factory delivered with option /A30.
Pin assignment:
Connection
Type
Option
Signal
Upper connector 1 (+) 2 (-)
E / T
/K1, /K2, /K3, /K6, /K7, /K8,
/K9, /K10
Single limit switch, Two limit switches /K3, /K8, /K9, /
K10: lower switch, e.g. MIN MAX ==> MIN
Upper connector 3 (+) 4 (-)
E / T
/K3, /K8, /K9, /K10
Single limit switch, Two limit switches /K3, /K8, /K9, /
K10: upper switch, e.g. MIN MAX ==> MAX
Lower connector 1 (+) 2 (-)
E
Electronic transmitter, 4-20 mA supply
Lower connector 3 (+) 4 (-)
E
/CP
Electronic transmitter, pulse output (option /CP)
Fig. 3-8
Summary of Contents for RAKD series
Page 2: ...Blank Page ...