2-1
IM MV100-17E
Using the Ethernet Interface
2
2.1
Ethernet Interface Specifications
Basic Specifications
Electrical and mechanical specifications
Conforms to IEEE 802.3
(Ethernet frames conform to the DIX specifications.)
Transmission medium type
10BASE-T
Protocol
TCP, IP, UDP, ICMP, ARP
The maximum number of connections and the number of simultaneous uses
The following table indicates the number of simultaneous uses (number of users that
can use the function simultaneously), the maximum number of connections, and the
port number for each function.
Function
Maximum Number
Number of
Port Number*
1
of Connections
Simultaneous Uses
(Fixed)
Administrator
User
Setting/
3
1
2*
2
34260/tcp
measurement
server
Maintenance/
1
1
1*
2
34261/tcp
test server
FTP server
2
2
2*
2
21/tcp
Instrument
–
–
–
34264/udp
information
server
*1 Port numbers are fixed.
*2 There are user limitations. For details, see “Granting Access Authority” in section 1.2.
Chapter 2 Using the Ethernet Interface