3-17
IM 04L57B01-01JA
Reconfiguring and Managing the W
ireless Input Unit (GX/GP/GM)
1
2
3
4
5
6
App
Color
Setup Item
Selectable Range or Options
Default Value
Color
24 colors (red, green, blue, blue violet, brown,
orange, yellow-green, light blue, violet, gray,
lime, cyan, dark blue, yellow, light gray, purple,
black, pink, light brown, light green, dark gray,
olive, dark cyan, and spring green) and a user-
defined color (1 color)
—
Color
Set channel display colors. The colors apply to the trend display and bar graph display.
For instructions on how to set user-defined colors, see the following manual.
GX/GP User’s Manual
Section 1.2.3, “Setting the Display”
GM User’s Manual
“Operation example 2” in section 2.1.6, “Changing the Settings”
Zone
Setup Item
Selectable Range or Options
Default Value
Lower
0 to 95%
0
Upper
5 to 100% input
100
Lower and Upper
Set these values when you want to divide the waveform displays of channels into
separate zones so that waveforms do not overlap. Set the
Lower
and
Upper
positions as
percentages of the maximum display width. Set
Lower
to a value less than
Upper
, and set
the zone width (
Upper
–
Lower
) to be 5% or greater.
For zone display examples, see the following manual.
GX/GP User’s Manual
Section 1.2.3, “Setting the Display”
GM User’s Manual
Section 2.1.6, “Changing the Settings”
Scale (GX/GP only)
Setup Item
Selectable Range or Options
Default Value
Position
Off/1/2/3/4/5/6/7/8/9/10
1
Division
4/5/6/7/8/9/10/11/12/C10
10
Position
Set the scale display position of the trend display. Set this to
Off
to not display scales.
Division
Set the number of divisions to make with the main scale marks.
C10: The scale is equally divided into 10 sections by main scale marks, and scale values are
indicated at 0, 30, 50, 70, and 100% positions.
For scale display examples, see the following manual.
GX/GP User’s Manual
Section 1.2.3, “Setting the Display”
Bar graph
Setup Item
Selectable Range or Options
Default Value
Base position
Lower, Center, Upper
Lower
Division
4/5/6/7/8/9/10/11/12
10
Base position
Set the bar graph base position.
This setting is applied when you are displaying the current value on the scale as a bar graph
on the bar graph and trend displays.
3.4 Configuring the Settings for Wireless Input Unit Data