Appx. C-3
IM 34M06H45-01E
7th Edition : Aug.30, 2019-00
(2) Preparing a cable-connector set
(1) Peel off about 60-mm length of outer vinyl
insulation from the cable.
60
mm
Vinyl
insulation
Tin-plated soft-copper
braided shield
(2) Remove the exposed tin-plated soft-
copper braided shield, aluminum-mylar
tape, and plastic stuffing. Take care not
to damage the exposed drain wire.
Tin-plated soft-
copper braided
shield
Drain wire
Aluminum-mylar
tape
Plastic
stuffing
Twist
pair
(3) Straighten the exposed twisted wires.
(4) Apply an insulation tube onto the drain
wire and shrink the tube with a heat gun.
Insulation tube
Approx. 8 mm