B6-11
IM 34M06H45-01E
7th Edition : Aug.30, 2019-00
B6.3.3 Operation Control in CPU Configuration
How to set up operation control using WideField3
To set up operation control using WideField3, use the following procedure.
1. Select [Project]
–[Project Settings] from the WideField3 menu bar.
2. Select [Error Handling Setup] from the Configuration pane of the displayed Project
Settings/Configuration window.
3. Select [Continue to run] or [Stop] for [I/O module Error] and [Subunit Communication
Error] under Error-Time Action Setup.
Figure B6.6 Setting Operation Control using WideField3
How to set up Operation Control using BASIC (F3BP
)
An I/O module error or subunit communications error generates an error in BASIC.
Design your application program to handle such errors..