vii
TI 33Q01J30-01E
Instruction on Contact Input Mode Wiring
[A1BD5D is added]
Instruction on Voltage Input Mode Wiring
[A1BD5D is added]
Appendix 1.1
Lists of CSA NI Compliant Products and CSA NI Parameters
Table The List of CSA NI Compliant Products <for FIO>
[A1BD5D, A1BA4D, A1BR4D, an A1BT4D are added]
Table FIO Parameters (The Load Devices)
[A1BD5D is added]
Appendix 1.2
Lists of FM NI Compliant Products and FM NI Parameters
The List of FM NI Compliant Products
Table The List of FM NI Compliant Products
[A1BD5D, A1BA4D, A1BR4D, an A1BT4D are added]
Parameters of FM NI Compliant Equipments
Table FIO Parameters (The Load Devices)
[A1BD5D is added]
Appendix 2
Lists of Type "n" Compliant Products
The List of Type "n" Compliant Products
Table The List of Type "n" Compliant Products <for FIO>
[A1BD5D, A1BA4D, A1BR4D, an A1BT4D are added]
Mar. 2015/15th Edition
Introduction
[Revised descriptive texts]
Safety Precautions
Safety, Protection, and Modification of the Product [Added a symbol]
1.2
Explosion Protection Standard in Each Country
[Deleted]
ATEX Directive [Exchanged CENELEC to ATEX]
1.3
Classification of Explosion Protection Equipment
Table Classification of Hazardous Area [Changed the classification]
Classification of Explosive Gas [Exchanged CENELEC to ATEX]
2.1
Explosion Protection Standards that CENTUM has Acquired
Table Explosion Protection Standards that CENTUM Complies
[Revised Conformed standard number]
2.2
Explosion Protection Construction that I/O Devices of CENTUM Comply
[Added note for safety barrier]
2.3
Overview of Connecting CENTUM to the Devices Installed in a Hazardous Area
Overview of Connecting a Module with Built-in Barrier (Equipment Compliant with Intrinsic Safety
Explosion Protection) with Devices
[Exchanged CENELEC to ATEX]
Figure Connection of a Module with Built-in Barrier (Compliant with CENELEC Standard) (1)
[Deleted Type “n” explosion protection equipment]
Figure Connection of a Module with Built-in Barrier (Compliant with CENELEC Standard) (2)
[Deleted Type “n” explosion protection equipment]
Figure Connection of a Type “n” Compliant Module (2)
[Added note for safety barrier]
Figure Connection of an NI Compliant Module (1)
[Exchanged “Flameproof wiring” to “Wiring for Div.1/Div.2” and deleted note]
Figure Connection of an NI Compliant Module (2)
[Exchanged “Flameproof wiring” to “Wiring for Div.1/Div.2” and deleted note]
Overview of connecting N-IO components
[Added]
3.1.1
Approved Types and Standards [Deleted Standards]
3.1.2
FM NI (FM Non-Incendive)
[Exchanged CENELEC to ATEX]
3.2
Complied Standards
[Deleted Standards]
4.1.1
Intrinsic Safety Explosion Protection of CENELEC Standard
[Exchanged CENELEC to ATEX]
Appendix 3
Lists of Parameters of Modules with Built-in Barrier
Table List of Parameters (CENELEC) of Modules with Built-in Barrier
[Exchanged CENELEC to ATEX]
June 2015/16th Edition
1.4
Symbols That Indicate Specifications of Explosion Protection
[The example symbols and explanation is changed]
2.1
Explosion Protection Standards that CENTUM has Acquired
Table Explosion Protection Standards that CENTUM Complies
[A2BN5D is added]
June 30, 2015-00