12-10
IM 01E30D01-01EN
<12. OUTLINE>
*5: Allowable fluid pressure should also be limited according to fluid temperature and pressure.
*6: Even when DIN PN10, 16, or 40 is required for a model of size 25 to 50 mm (1.0 to 2.0 in.), select PN40 (Process connection code:
AD4) because there is no difference in the dimensions of the mating faces.
Even when DIN PN10 or 16 is required for a model of size 65 to 150 mm (2.5 to 6.0 in.), select PN16 (Process connection code: AD2)
because there is no difference in the dimensions of the mating faces.
*7: The dimensions of lay length code 1 are the same as those of the PFA lining standard lay length (lay length code 1) in the AXF series.
For details, read “EXTERNAL DIMENSIONS”.
*8: Excluding the size of 65 mm, dimensions of lay length code 2 are the same as those of PFA lining replacement models (lay length code
2) in AXF series. Lay lengths for special gaskets (optional codes GA, GC, GD) are different. For details, read “EXTERNAL DIMEN
-
SIONS”.
*9: For an explosion proof type except for TIIS, select “ANSI 1/2 NPT female” or “ISO M20 × 1.5 female”.
For the TIIS flameproof type, select “JIS G1/2 female” and optional code G11.
*10: Select from among the figures at the right.
1
2
N
F1207.ai
*11: In the case of the TIIS flameproof type, select “with indicator” (code 1 or 2).
*12: Output signal code “-E”: HART 5.(Output signal code “-J” is recommended for HART communication.)
*13: Output signal code “-J”: HART 5 or HART7 selectable. Specify HART 5 or HART 7 when ordering.