APPENDIX C
SPECIFICATIONS
Operating Modes
Output Frequency: 2048000b/s +/-25ppm (0 to 70C)
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
E1 Framed (FAS, CAS, CRC-4, CRC-4+CAS)
Fractional E1
Nx64 kb/s (N=1 to 31)
Contiguous or Noncontiguous Channel Selections
E1 Codes (AMI, HDB3)
Signaling Bits Transmit/Receive
Tester Loopback
Idle Codes (7E, 7F, FF)
Receive Input
Input Frequency: 2048000 b/s +/-50ppm
Sensitivity: 0 to -43 dB (up to 6000ft.)
Input Impedance
TERM: 120 ohms nominal
DSX: 120 ohms nominal
Bridge: 1000 ohms nominal
Output Specifications
Line Build Out (DSX-1): 120 Ohms Line.
Line Build Out (DS1): 0dB.
Meets the latest E1 specifications including ITU G.703, G.704, G.706, G.823, AND I.431 as well
as ETS 300 011, 300 166, TBR 12 and TBR 13.
Line codes
AMI and HDB3
Error Injection
Logic Errors: Single or rate
Rate: 1E-1 to 1E-7
Patterns
Pseudorandom patterns:
2E3-1, 2E4-1, 2E5-1, 2E6-1, 2E7-1, 2E9-1, 2E10-1, 2E11-1(2047), 2E15-1,
2E15-1 Inverted, 2E17-1, 2E18-1, 2E20-1(O.153), 2E20-1(QRSS), 2E20-1 Inverted, 2E21-1,
2E22-1, 2E23-1(O.151), 2E23-1 Inverted, 2E25-1, 2E28-1,
2E29-1, 2E31-1, 2E32-1
Repetitive patterns:
All Ones, All Zeros, Alternating Ones and Zeros, Double Alternating Ones and Zeros, 3 in 24, 1 in
16, 1 in 8, 1 in 4.
Loop Code Generation
Fractional E1 Idle Channels loop-up and loop-down.
Power
External, Input 220VAC/Output 9VDC@300MA Internal, 4AA Nickel-Metal Hydride.
14