OPERATING INSTRUCTIONS
This unit has many features which are different from those found on conventional units. The servicer must be
familiar with these features in order to properly service the unit
Check the data specification plate and ensure the proper voltage and current rating for the type of plug on the
unit is available.
DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER CORD.
See Fig 1 for the types of acceptable plugs. Do not use an extension cord for the installation of this product.
Refer to the data specification plate for electrical requirements.
LCDI Cords
Underwriters Laboratories and the National Electric Code (NEC) now require power cords that can sense
current leakage and open the electrical circuit to the unit on units rated at 250 volts or less. In the event that
unit does not operate, check the reset button located on or near the head of the power cord as part of the
normal troubleshooting procedure.
VOLTAGE MEASUREMENTS
Before connecting the unit, measure the supply voltage. Voltage must within the voltage utilization range
given in Table 1.
Operating Voltage
Unit Voltage Rating
Voltage Utilization Range
Minimum
Maximum
230/208
187
253
115
103
126
Table 1.
Summary of Contents for TTWA Series
Page 10: ...YMGI Your Modern Green Idea 10...
Page 27: ...YMGI Your Modern Green Idea 27 OPERATING INSTRUCTIONS...
Page 37: ...YMGI Your Modern Green Idea 37 TTWA Wiring Diagrams TTWA0 Wiring Diagram AC Only...
Page 38: ...YMGI Your Modern Green Idea 38 TTWA0 Wiring Diagram AC Heater...
Page 39: ...YMGI Your Modern Green Idea 39 TTWA0 Wiring Diagram HP...
Page 40: ...YMGI Your Modern Green Idea 40 TTWA0 Wiring Diagram HP Heater...