The Low batter voltage trip point can be customized from defaulted value 10VDC to 10.5VDC thru the SW1
on DIP switch.
The inverter will go to Over temp protection when heat sink temp. ≥105º
C, and go to Fault (shutdown
Output) after 30 seconds. The switch has to be reset to activate the inverter.
The APC series Inverter is with back feeding protection which avoids presenting an AC voltage on the AC
input terminal in Invert mode.
After the reason for fault is cleared, the inverter has to be reset to start working.
2.5.8 Remote control
Apart from the switch panel on the front of the inverter, an
extra switch panel connected to the RJ11 port at the DC side of
the inverter thru a standard telephone cable can also control the
operation of the inverter.
If an extra switch panel is connected to the inverter via “remote
control port”, together with the panel on the inverter case, the
two panels will be connected and operated in parallel.
Whichever first switches from “Off” to “Power saver off” or
“Power saver on”, it will power the inverter on.
If the commands from the two panels conflict, the inverter will
accept command according to the following priority:
Power saver on> Power saver off> Power off
Only when both panels are turned to “Unit Off” position, the inverter will be powered off.
2.5.9 LED Indicator & LCD
SHORE POWER ON
GREEN LED lighting on AC Mode
INVERTER ON
GREEN LED lighting on Inverter Mode
FAST CHARGE
Yellow LED lighting on Fast Charging Mode
FLOAT CHARGE
GREEN LED lighting on Float Charging Mode
OVER TEMP TRIP
RED LED lighting on Over Temperature
OVER LOAD TRIP
RED LED lighting on Over Load
POWER SAVER ON
GREEN LED lighting on Power Saver Mode (Power
Saver Load
≦
25W)