Yiyuan Electric Co., Ltd www.yiyen.com
11
The inverter is factory defaulted to detect load for 250ms in every 30 seconds. This cycle can be customized
to 3 seconds thru the SW3 on DIP switch.
Note: The minimum power of load to take inverter out of sleep mode (Power Saver On) is 25 Watts.
AnyPower Combi Series Idle Power Consumption
Model
Power Saver Off
Power Saver Auto
Idle
3Secs(Max)
30Secs(MAX)
1000W
42W
16W
10W
1500W
48W
20W
10W
2000W
60W
25W
10W
3000W
72W
28W
12W
4000W
120W
45W
15W
5000W
135W
50W
18W
6000W
145W
55W
18W
2.5.5 Transfer
While in the Standby Mode, the AC input is continually monitored. Whenever AC power falls below the
VAC Trip voltage (154 VAC, default setting), the inverter automatically transfers back to the Invert Mode
with minimum interruption to your appliances - as long as the inverter is turned on. The transfer from
Standby mode to Inverter mode occurs in approximately 10 milliseconds. And it is the same time from
Inverter mode to Standby mode.
There is a 15-second delay from DC to AC.
2.5.6 Automatic Voltage Regulation*
The automatic voltage regulation function is only for APS Pure Sine Wave Inverter/ Charger
which is
a combination of APC inverter and Automatic Voltage Regulator.
Instead of simply bypassing the input AC to power the loads, the APS series inverter stabilizes the input AC
voltage to a range of 230V/120V
±
10%.
Connected with batteries, the APS inverter will function as a UPS with max transfer time of 10 ms.
With all the unique features from the inverter and AVR, it brings you long-term trouble free operation
beyond your expectation.
APS Series AVR Function Introduction